Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
811 | 3048 | 19.7 | 66% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
6 | 4 | GASTROENTEROLOGY & HEPATOLOGY//ONCOLOGY//SURGERY | 1371034 |
260 | 3 | NUCL MED//RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING//JOURNAL OF NUCLEAR MEDICINE | 44690 |
1166 | 2 | IEEE TRANSACTIONS ON NUCLEAR SCIENCE//SILICON PHOTOMULTIPLIER//PHYSICS IN MEDICINE AND BIOLOGY | 9394 |
811 | 1 | SILICON PHOTOMULTIPLIER//SIPM//DEPTH OF INTERACTION | 3048 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | SILICON PHOTOMULTIPLIER | authKW | 1469705 | 7% | 71% | 207 |
2 | SIPM | authKW | 979408 | 5% | 67% | 145 |
3 | DEPTH OF INTERACTION | authKW | 768193 | 3% | 91% | 84 |
4 | IEEE TRANSACTIONS ON NUCLEAR SCIENCE | journal | 638659 | 34% | 6% | 1027 |
5 | DEPTH OF INTERACTION DOI | authKW | 514928 | 2% | 92% | 56 |
6 | POSITRON EMISSION TOMOGRAPHY PET | authKW | 456657 | 9% | 16% | 289 |
7 | MPPC | authKW | 427320 | 2% | 67% | 64 |
8 | GAMMA CAMERA SPECT PET PET CT CORONARY CT ANGIOGRAPHY CTA | authKW | 322982 | 2% | 50% | 64 |
9 | SILICON PHOTOMULTIPLIER SIPM | authKW | 261046 | 1% | 74% | 35 |
10 | TIME OF FLIGHT PET | authKW | 244192 | 1% | 76% | 32 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Nuclear Science & Technology | 120538 | 58% | 1% | 1767 |
2 | Instruments & Instrumentation | 26389 | 29% | 0% | 896 |
3 | Spectroscopy | 20714 | 23% | 0% | 697 |
4 | Physics, Nuclear | 18486 | 24% | 0% | 720 |
5 | Physics, Particles & Fields | 15424 | 24% | 0% | 727 |
6 | Radiology, Nuclear Medicine & Medical Imaging | 14382 | 27% | 0% | 827 |
7 | Engineering, Electrical & Electronic | 11862 | 37% | 0% | 1137 |
8 | Engineering, Biomedical | 9048 | 14% | 0% | 428 |
9 | Imaging Science & Photographic Technology | 503 | 2% | 0% | 61 |
10 | Computer Science, Interdisciplinary Applications | 89 | 2% | 0% | 65 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | PHYS MOL IMAGING SYST | 116545 | 1% | 73% | 16 |
2 | SHERBROOKE MOL IMAGING | 67301 | 1% | 31% | 22 |
3 | NUCL MED PHYS GRP | 61348 | 0% | 88% | 7 |
4 | DIGITAL SYST DESIGN GRP | 60098 | 0% | 100% | 6 |
5 | MOL IMAGING RUMENTAT | 50082 | 0% | 100% | 5 |
6 | INTERDISCIPLINARY PROGRAMS RADIAT PL LIFE SCI M | 45070 | 0% | 75% | 6 |
7 | COMMUN DIGITAL SYST DESIGN GRP DSDC | 41733 | 0% | 83% | 5 |
8 | DETECTOR DEV GRP | 40057 | 0% | 50% | 8 |
9 | GUYS ST THOMAS CLIN PET | 32775 | 0% | 55% | 6 |
10 | RADIAT DETECT MED IMAGING | 32775 | 0% | 55% | 6 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | IEEE TRANSACTIONS ON NUCLEAR SCIENCE | 638659 | 34% | 6% | 1027 |
2 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 115460 | 23% | 2% | 690 |
3 | PHYSICS IN MEDICINE AND BIOLOGY | 103860 | 11% | 3% | 336 |
4 | JOURNAL OF INSTRUMENTATION | 48335 | 5% | 3% | 142 |
5 | JOURNAL OF NUCLEAR MEDICINE | 12012 | 4% | 1% | 111 |
6 | IEEE TRANSACTIONS ON MEDICAL IMAGING | 9094 | 2% | 2% | 59 |
7 | MEDICAL PHYSICS | 4241 | 2% | 1% | 70 |
8 | ANNALS OF NUCLEAR MEDICINE | 2735 | 1% | 1% | 23 |
9 | EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING | 1761 | 1% | 1% | 24 |
10 | EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1741 | 1% | 1% | 24 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | SILICON PHOTOMULTIPLIER | 1469705 | 7% | 71% | 207 | Search SILICON+PHOTOMULTIPLIER | Search SILICON+PHOTOMULTIPLIER |
2 | SIPM | 979408 | 5% | 67% | 145 | Search SIPM | Search SIPM |
3 | DEPTH OF INTERACTION | 768193 | 3% | 91% | 84 | Search DEPTH+OF+INTERACTION | Search DEPTH+OF+INTERACTION |
4 | DEPTH OF INTERACTION DOI | 514928 | 2% | 92% | 56 | Search DEPTH+OF+INTERACTION+DOI | Search DEPTH+OF+INTERACTION+DOI |
5 | POSITRON EMISSION TOMOGRAPHY PET | 456657 | 9% | 16% | 289 | Search POSITRON+EMISSION+TOMOGRAPHY+PET | Search POSITRON+EMISSION+TOMOGRAPHY+PET |
6 | MPPC | 427320 | 2% | 67% | 64 | Search MPPC | Search MPPC |
7 | GAMMA CAMERA SPECT PET PET CT CORONARY CT ANGIOGRAPHY CTA | 322982 | 2% | 50% | 64 | Search GAMMA+CAMERA+SPECT+PET+PET+CT+CORONARY+CT+ANGIOGRAPHY+CTA | Search GAMMA+CAMERA+SPECT+PET+PET+CT+CORONARY+CT+ANGIOGRAPHY+CTA |
8 | SILICON PHOTOMULTIPLIER SIPM | 261046 | 1% | 74% | 35 | Search SILICON+PHOTOMULTIPLIER+SIPM | Search SILICON+PHOTOMULTIPLIER+SIPM |
9 | TIME OF FLIGHT PET | 244192 | 1% | 76% | 32 | Search TIME+OF+FLIGHT+PET | Search TIME+OF+FLIGHT+PET |
10 | TOF PET | 237107 | 1% | 72% | 33 | Search TOF+PET | Search TOF+PET |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | ZHANG, YX , YAN, H , BAGHAEI, H , WONG, WH , (2016) A NOVEL DEPTH-OF-INTERACTION BLOCK DETECTOR FOR POSITRON EMISSION TOMOGRAPHY USING A DICHOTOMOUS ORTHOGONAL SYMMETRY DECODING CONCEPT.PHYSICS IN MEDICINE AND BIOLOGY. VOL. 61. ISSUE 4. P. 1608 -1633 | 60 | 90% | 1 |
2 | RONCALI, E , CHERRY, SR , (2011) APPLICATION OF SILICON PHOTOMULTIPLIERS TO POSITRON EMISSION TOMOGRAPHY.ANNALS OF BIOMEDICAL ENGINEERING. VOL. 39. ISSUE 4. P. 1358 -1377 | 63 | 82% | 63 |
3 | LEWELLEN, TK , (2008) RECENT DEVELOPMENTS IN PET DETECTOR TECHNOLOGY.PHYSICS IN MEDICINE AND BIOLOGY. VOL. 53. ISSUE 17. P. R287 -R317 | 69 | 78% | 104 |
4 | DEL GUERRA, A , BELCARI, N , BISOGNI, M , (2016) POSITRON EMISSION TOMOGRAPHY: ITS 65 YEARS.RIVISTA DEL NUOVO CIMENTO. VOL. 39. ISSUE 4. P. 155 -223 | 74 | 67% | 1 |
5 | KIM, E , HONG, KJ , YEOM, JY , OLCOTT, PD , LEVIN, CS , (2013) TRENDS OF DATA PATH TOPOLOGIES FOR DATA ACQUISITION SYSTEMS IN POSITRON EMISSION TOMOGRAPHY.IEEE TRANSACTIONS ON NUCLEAR SCIENCE. VOL. 60. ISSUE 5. P. 3746-3757 | 71 | 79% | 1 |
6 | SURTI, S , KARP, JS , (2016) ADVANCES IN TIME-OF-FLIGHT PET.PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS. VOL. 32. ISSUE 1. P. 12 -22 | 63 | 72% | 2 |
7 | LECOMTE, R , (2009) NOVEL DETECTOR TECHNOLOGY FOR CLINICAL PET.EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. VOL. 36. ISSUE . P. 69-85 | 77 | 73% | 31 |
8 | TAI, YC , LAFOREST, R , (2005) INSTRUMENTATION ASPECTS OF ANIMAL PET.ANNUAL REVIEW OF BIOMEDICAL ENGINEERING. VOL. 7. ISSUE . P. 255 -285 | 91 | 63% | 52 |
9 | BISOGNI, MG , MORROCCHI, M , (2016) DEVELOPMENT OF ANALOG SOLID-STATE PHOTO-DETECTORS FOR POSITRON EMISSION TOMOGRAPHY.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. VOL. 809. ISSUE . P. 140 -148 | 53 | 83% | 1 |
10 | SCHAART, DR , CHARBON, E , FRACH, T , SCHULZ, V , (2016) ADVANCES IN DIGITAL SIPMS AND THEIR APPLICATION IN BIOMEDICAL IMAGING.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. VOL. 809. ISSUE . P. 31 -52 | 48 | 66% | 6 |
Classes with closest relation at Level 1 |