Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
9211 | 1177 | 13.2 | 47% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
4 | 4 | ENVIRONMENTAL SCIENCES//GEOSCIENCES, MULTIDISCIPLINARY//METEOROLOGY & ATMOSPHERIC SCIENCES | 1766162 |
347 | 3 | JOURNAL OF ENVIRONMENTAL RADIOACTIVITY//RADON//NUCLEAR SCIENCE & TECHNOLOGY | 35941 |
1879 | 2 | APPLIED RADIATION AND ISOTOPES//GAMMA RAY SPECTROMETRY//NUCLEAR SCIENCE & TECHNOLOGY | 6007 |
9211 | 1 | GAMMA RAY SPECTROMETRY//EFFICIENCY CALIBRATION//COINCIDENCE SUMMING | 1177 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | GAMMA RAY SPECTROMETRY | authKW | 1569516 | 17% | 30% | 203 |
2 | EFFICIENCY CALIBRATION | authKW | 1257383 | 6% | 68% | 71 |
3 | COINCIDENCE SUMMING | authKW | 1127724 | 4% | 91% | 48 |
4 | HPGE DETECTOR | authKW | 805433 | 8% | 32% | 97 |
5 | TRUE COINCIDENCE SUMMING | authKW | 681777 | 2% | 91% | 29 |
6 | FULL ENERGY PEAK EFFICIENCY | authKW | 548924 | 2% | 92% | 23 |
7 | SELF ATTENUATION | authKW | 525307 | 2% | 75% | 27 |
8 | COINCIDENCE SUMMING CORRECTIONS | authKW | 494127 | 2% | 95% | 20 |
9 | GAMMA SPECTROMETRY | authKW | 446682 | 8% | 17% | 99 |
10 | EFFICIENCY TRANSFER | authKW | 368946 | 1% | 89% | 16 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Nuclear Science & Technology | 100691 | 85% | 0% | 999 |
2 | Chemistry, Inorganic & Nuclear | 19028 | 45% | 0% | 529 |
3 | Radiology, Nuclear Medicine & Medical Imaging | 9139 | 34% | 0% | 405 |
4 | Instruments & Instrumentation | 8953 | 28% | 0% | 325 |
5 | Physics, Nuclear | 7297 | 24% | 0% | 281 |
6 | Spectroscopy | 6867 | 21% | 0% | 250 |
7 | Physics, Particles & Fields | 4711 | 21% | 0% | 251 |
8 | Chemistry, Analytical | 1518 | 16% | 0% | 194 |
9 | Physics, Atomic, Molecular & Chemical | 89 | 5% | 0% | 56 |
10 | Environmental Sciences | 68 | 6% | 0% | 66 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | MED EQUIPMENT TECHNOL | 261578 | 1% | 92% | 11 |
2 | REACTOR PROJECTS | 97774 | 1% | 54% | 7 |
3 | BUNDESAMT EICH VERMESSUNGSWESEN | 77825 | 0% | 100% | 3 |
4 | NUCL COMPETENCE KNOWLEDGE MANAGEMENT | 69175 | 0% | 67% | 4 |
5 | CITIUS | 58943 | 1% | 23% | 10 |
6 | ST KLIMENT OHRIDSKY | 51884 | 0% | 100% | 2 |
7 | MINERAL PETROG MICROPEDOL | 38910 | 0% | 50% | 3 |
8 | SERV RADIOISOTOPOS | 36023 | 0% | 28% | 5 |
9 | ESPE OMETRIA GAMMA | 34588 | 0% | 67% | 2 |
10 | RADIACTIVIDAD AMBIENTAL | 31121 | 1% | 20% | 6 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | APPLIED RADIATION AND ISOTOPES | 364215 | 30% | 4% | 353 |
2 | JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY | 39044 | 11% | 1% | 128 |
3 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 37968 | 21% | 1% | 246 |
4 | NUCLEAR TECHNOLOGY & RADIATION PROTECTION | 13460 | 1% | 4% | 14 |
5 | ROMANIAN REPORTS IN PHYSICS | 9641 | 2% | 2% | 20 |
6 | INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES | 7962 | 2% | 2% | 18 |
7 | JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES | 5797 | 2% | 1% | 28 |
8 | RADIATION PHYSICS AND CHEMISTRY | 3070 | 3% | 0% | 34 |
9 | ROMANIAN JOURNAL OF PHYSICS | 3046 | 1% | 1% | 12 |
10 | ACCREDITATION AND QUALITY ASSURANCE | 2904 | 1% | 1% | 12 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | GAMMA RAY SPECTROMETRY | 1569516 | 17% | 30% | 203 | Search GAMMA+RAY+SPECTROMETRY | Search GAMMA+RAY+SPECTROMETRY |
2 | EFFICIENCY CALIBRATION | 1257383 | 6% | 68% | 71 | Search EFFICIENCY+CALIBRATION | Search EFFICIENCY+CALIBRATION |
3 | COINCIDENCE SUMMING | 1127724 | 4% | 91% | 48 | Search COINCIDENCE+SUMMING | Search COINCIDENCE+SUMMING |
4 | HPGE DETECTOR | 805433 | 8% | 32% | 97 | Search HPGE+DETECTOR | Search HPGE+DETECTOR |
5 | TRUE COINCIDENCE SUMMING | 681777 | 2% | 91% | 29 | Search TRUE+COINCIDENCE+SUMMING | Search TRUE+COINCIDENCE+SUMMING |
6 | FULL ENERGY PEAK EFFICIENCY | 548924 | 2% | 92% | 23 | Search FULL+ENERGY+PEAK+EFFICIENCY | Search FULL+ENERGY+PEAK+EFFICIENCY |
7 | SELF ATTENUATION | 525307 | 2% | 75% | 27 | Search SELF+ATTENUATION | Search SELF+ATTENUATION |
8 | COINCIDENCE SUMMING CORRECTIONS | 494127 | 2% | 95% | 20 | Search COINCIDENCE+SUMMING+CORRECTIONS | Search COINCIDENCE+SUMMING+CORRECTIONS |
9 | GAMMA SPECTROMETRY | 446682 | 8% | 17% | 99 | Search GAMMA+SPECTROMETRY | Search GAMMA+SPECTROMETRY |
10 | EFFICIENCY TRANSFER | 368946 | 1% | 89% | 16 | Search EFFICIENCY+TRANSFER | Search EFFICIENCY+TRANSFER |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | THABET, AA , DLABAC, AD , JOVANOVIC, SI , BADAWI, MS , MIHALJEVIC, NN , EL-KHATIB, AM , GOUDA, MM , ABBAS, MI , (2015) EXPERIMENTAL VERIFICATION OF GAMMA-EFFICIENCY CALCULATIONS FOR SCINTILLATION DETECTORS IN ANGLE 4 SOFTWARE.NUCLEAR TECHNOLOGY & RADIATION PROTECTION. VOL. 30. ISSUE 1. P. 35 -46 | 32 | 97% | 0 |
2 | GOUDA, MM , BADAWI, MS , EL-KHATIB, AM , HUSSIEN, NS , ABBAS, MI , (2016) CALCULATION OF NAI(TL) DETECTOR FULL-ENERGY PEAK EFFICIENCY USING THE EFFICIENCY TRANSFER METHOD FOR SMALL RADIOACTIVE CYLINDRICAL SOURCES.NUCLEAR TECHNOLOGY & RADIATION PROTECTION. VOL. 31. ISSUE 2. P. 150 -158 | 30 | 100% | 0 |
3 | EKE, C , BOZTOSUN, I , (2014) GAMMA-RAY SPECTROMETRY FOR THE SELF-ATTENUATION CORRECTION FACTOR OF THE SAND SAMPLES FROM ANTALYA IN TURKEY.JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY. VOL. 301. ISSUE 1. P. 103-108 | 30 | 100% | 1 |
4 | LEPY, MC , PEARCE, A , SIMA, O , (2015) UNCERTAINTIES IN GAMMA-RAY SPECTROMETRY.METROLOGIA. VOL. 52. ISSUE 3. P. S123 -S145 | 35 | 69% | 10 |
5 | EL-KHATIB, AM , GOUDA, MM , BADAWI, MS , HAMZAWY, A , HUSSIEN, NS , ABBAS, MI , (2016) CALCULATION OF THE FULL-ENERGY PEAK EFFICIENCY OF NAI(TL) DETECTOR USING THE EFFICIENCY TRANSFER METHOD FOR LARGE RADIOACTIVE CYLINDRICAL SOURCES.CHINESE JOURNAL OF PHYSICS. VOL. 54. ISSUE 4. P. 592 -606 | 27 | 100% | 0 |
6 | BOSON, J , AGREN, G , JOHANSSON, L , (2008) A DETAILED INVESTIGATION OF HPGE DETECTOR RESPONSE FOR IMPROVED MONTE CARLO EFFICIENCY CALCULATIONS.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. VOL. 587. ISSUE 2-3. P. 304 -314 | 31 | 89% | 49 |
7 | MIHALJEVIC, N , DLABAC, A , JOVANOVIC, S , (2012) ACCOUNTING FOR DETECTOR CRYSTAL EDGE ROUNDING IN GAMMA-EFFICIENCY CALCULATIONS THEORETICAL ELABORATION AND APPLICATION IN ANGLE SOFTWARE.NUCLEAR TECHNOLOGY & RADIATION PROTECTION. VOL. 27. ISSUE 1. P. 1-12 | 27 | 100% | 6 |
8 | JACKMAN, KR , BIEGALSKI, SR , (2009) METHODS AND SOFTWARE FOR PREDICTING GERMANIUM DETECTOR ABSOLUTE FULL-ENERGY PEAK EFFICIENCIES.JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY. VOL. 279. ISSUE 1. P. 355 -360 | 30 | 94% | 9 |
9 | JONSSON, S , VIDMAR, T , RAMEBOCK, H , (2015) IMPLEMENTATION OF CALCULATION CODES IN GAMMA SPECTROMETRY MEASUREMENTS FOR CORRECTIONS OF SYSTEMATIC EFFECTS.JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY. VOL. 303. ISSUE 3. P. 1727 -1736 | 25 | 93% | 2 |
10 | YUCEL, H , SOLMAZ, AN , KOSE, E , BOR, D , (2010) A SEMI-EMPIRICAL METHOD FOR CALCULATION OF TRUE COINCIDENCE CORRECTIONS FOR THE CASE OF A CLOSE-IN DETECTION IN GAMMA-RAY SPECTROMETRY.JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY. VOL. 283. ISSUE 2. P. 305-312 | 27 | 96% | 5 |
Classes with closest relation at Level 1 |