Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
7267 | 1388 | 22.4 | 54% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
8 | 4 | CARDIAC & CARDIOVASCULAR SYSTEM//PERIPHERAL VASCULAR DISEASES//CARDIOL | 1276458 |
309 | 3 | MECHANICAL VENTILATION//CRITICAL CARE MEDICINE//DELIRIUM | 40181 |
947 | 2 | ACUTE RESPIRATORY DISTRESS SYNDROME//MECHANICAL VENTILATION//VENTILATOR INDUCED LUNG INJURY | 10903 |
7267 | 1 | CAPNOGRAPHY//VOLUMETRIC CAPNOGRAPHY//TRANSCUTANEOUS CARBON DIOXIDE | 1388 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | CAPNOGRAPHY | authKW | 612348 | 7% | 29% | 96 |
2 | VOLUMETRIC CAPNOGRAPHY | authKW | 343438 | 2% | 71% | 22 |
3 | TRANSCUTANEOUS CARBON DIOXIDE | authKW | 323356 | 2% | 70% | 21 |
4 | CAPNOMETRY | authKW | 316956 | 3% | 39% | 37 |
5 | END TIDAL CARBON DIOXIDE | authKW | 183089 | 2% | 26% | 32 |
6 | BLOOD GAS MONITORING | authKW | 179624 | 2% | 39% | 21 |
7 | RESPIRATORY DEAD SPACE | authKW | 159006 | 2% | 34% | 21 |
8 | MEASUREMENT TECHNIQUES CAPNOMETRY | authKW | 156428 | 1% | 89% | 8 |
9 | TRANSCUTANEOUS PCO2 | authKW | 148481 | 1% | 75% | 9 |
10 | TRANSCUTANEOUS | authKW | 118544 | 2% | 19% | 29 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Anesthesiology | 19241 | 22% | 0% | 312 |
2 | Critical Care Medicine | 11302 | 18% | 0% | 247 |
3 | Respiratory System | 3035 | 13% | 0% | 175 |
4 | Peripheral Vascular Diseases | 1250 | 9% | 0% | 131 |
5 | Emergency Medicine | 1241 | 4% | 0% | 58 |
6 | Pediatrics | 1111 | 11% | 0% | 147 |
7 | Surgery | 479 | 12% | 0% | 166 |
8 | Engineering, Biomedical | 225 | 4% | 0% | 52 |
9 | Medical Informatics | 154 | 1% | 0% | 20 |
10 | Physiology | 134 | 4% | 0% | 61 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | MAGILL ANAESTHESIA INTENS CARE MED PAIN MA | 43996 | 0% | 100% | 2 |
2 | DIABET WOUND | 29329 | 0% | 67% | 2 |
3 | ABRAHAM LINCOLN MED PEDIAT | 21998 | 0% | 100% | 1 |
4 | ACOUST UNITE MIXTE RECH | 21998 | 0% | 100% | 1 |
5 | ANAESTHESIAHYPERBARIC UNIT | 21998 | 0% | 100% | 1 |
6 | ANESTHESIA INTENS CARE PAIN | 21998 | 0% | 100% | 1 |
7 | ANESTHESIOL INTENS CARE PRE HOSP EMERGENCY | 21998 | 0% | 100% | 1 |
8 | BIOL CHEM NUTR 3 | 21998 | 0% | 100% | 1 |
9 | BR MED | 21998 | 0% | 100% | 1 |
10 | BSRC PROGRAM | 21998 | 0% | 100% | 1 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | JOURNAL OF CLINICAL MONITORING | 34811 | 2% | 6% | 27 |
2 | JOURNAL OF CLINICAL MONITORING AND COMPUTING | 19388 | 2% | 3% | 26 |
3 | CRITICAL CARE MEDICINE | 16585 | 7% | 1% | 94 |
4 | RESPIRATORY CARE | 12500 | 2% | 2% | 32 |
5 | ANESTHESIA AND ANALGESIA | 4825 | 4% | 0% | 57 |
6 | CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 4719 | 2% | 1% | 28 |
7 | VASA-JOURNAL OF VASCULAR DISEASES | 3312 | 1% | 1% | 17 |
8 | BRITISH JOURNAL OF CLINICAL EQUIPMENT | 3141 | 0% | 14% | 1 |
9 | ANGIOLOGY | 2966 | 2% | 1% | 25 |
10 | ACUTE CARE | 2835 | 0% | 6% | 2 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | CAPNOGRAPHY | 612348 | 7% | 29% | 96 | Search CAPNOGRAPHY | Search CAPNOGRAPHY |
2 | VOLUMETRIC CAPNOGRAPHY | 343438 | 2% | 71% | 22 | Search VOLUMETRIC+CAPNOGRAPHY | Search VOLUMETRIC+CAPNOGRAPHY |
3 | TRANSCUTANEOUS CARBON DIOXIDE | 323356 | 2% | 70% | 21 | Search TRANSCUTANEOUS+CARBON+DIOXIDE | Search TRANSCUTANEOUS+CARBON+DIOXIDE |
4 | CAPNOMETRY | 316956 | 3% | 39% | 37 | Search CAPNOMETRY | Search CAPNOMETRY |
5 | END TIDAL CARBON DIOXIDE | 183089 | 2% | 26% | 32 | Search END+TIDAL+CARBON+DIOXIDE | Search END+TIDAL+CARBON+DIOXIDE |
6 | BLOOD GAS MONITORING | 179624 | 2% | 39% | 21 | Search BLOOD+GAS+MONITORING | Search BLOOD+GAS+MONITORING |
7 | RESPIRATORY DEAD SPACE | 159006 | 2% | 34% | 21 | Search RESPIRATORY+DEAD+SPACE | Search RESPIRATORY+DEAD+SPACE |
8 | MEASUREMENT TECHNIQUES CAPNOMETRY | 156428 | 1% | 89% | 8 | Search MEASUREMENT+TECHNIQUES+CAPNOMETRY | Search MEASUREMENT+TECHNIQUES+CAPNOMETRY |
9 | TRANSCUTANEOUS PCO2 | 148481 | 1% | 75% | 9 | Search TRANSCUTANEOUS+PCO2 | Search TRANSCUTANEOUS+PCO2 |
10 | TRANSCUTANEOUS | 118544 | 2% | 19% | 29 | Search TRANSCUTANEOUS | Search TRANSCUTANEOUS |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | RESTREPO, RD , HIRST, KR , WITTNEBEL, L , WETTSTEIN, R , (2012) AARC CLINICAL PRACTICE GUIDELINE: TRANSCUTANEOUS MONITORING OF CARBON DIOXIDE AND OXYGEN: 2012.RESPIRATORY CARE. VOL. 57. ISSUE 11. P. 1955-1962 | 75 | 82% | 20 |
2 | AARRESTAD, S , TOLLEFSEN, E , KLEIVEN, AL , QVARFORT, M , JANSSENS, JP , SKJONSBERG, OH , (2016) VALIDITY OF TRANSCUTANEOUS PCO2 IN MONITORING CHRONIC HYPOVENTILATION TREATED WITH NON-INVASIVE VENTILATION.RESPIRATORY MEDICINE. VOL. 112. ISSUE . P. 112 -118 | 39 | 85% | 1 |
3 | TOBIAS, JD , (2009) TRANSCUTANEOUS CARBON DIOXIDE MONITORING IN INFANTS AND CHILDREN.PEDIATRIC ANESTHESIA. VOL. 19. ISSUE 5. P. 434 -444 | 39 | 95% | 42 |
4 | SCHEFFLER, A , RIEGER, H , (1992) CLINICAL INFORMATION-CONTENT OF TRANSCUTANEOUS OXYMETRY (TCPO2) IN PERIPHERAL ARTERIAL OCCLUSIVE DISEASE (A REVIEW OF THE METHODOLOGICAL AND CLINICAL LITERATURE WITH A SPECIAL REFERENCE TO CRITICAL LIMB ISCHEMIA).VASA-JOURNAL OF VASCULAR DISEASES. VOL. 21. ISSUE 2. P. 111-126 | 79 | 82% | 28 |
5 | LERMUZEAUX, M , MERIC, H , SAUNEUF, B , GIRARD, S , NORMAND, H , LOFASO, F , TERZI, N , (2016) SUPERIORITY OF TRANSCUTANEOUS CO2 OVER END-TIDAL CO2 MEASUREMENT FOR MONITORING RESPIRATORY FAILURE IN NONINTUBATED PATIENTS: A PILOT STUDY.JOURNAL OF CRITICAL CARE. VOL. 31. ISSUE 1. P. 150 -156 | 27 | 79% | 0 |
6 | BARTER, LS , HOPPER, K , (2011) TRANSCUTANEOUS MONITOR APPROXIMATES PACO2 BUT NOT PAO2 IN ANESTHETIZED RABBITS.VETERINARY ANAESTHESIA AND ANALGESIA. VOL. 38. ISSUE 6. P. 568 -575 | 31 | 76% | 0 |
7 | HOLOWAYCHUK, MK , FUJITA, H , BERSENAS, AME , (2014) EVALUATION OF A TRANSCUTANEOUS BLOOD GAS MONITORING SYSTEM IN CRITICALLY ILL DOGS.JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE. VOL. 24. ISSUE 5. P. 545 -553 | 25 | 83% | 1 |
8 | GORSKA, K , KORCZYNSKI, P , MASKEY-WARZECHOWSKA, M , CHAZAN, R , KRENKE, R , (2015) VARIABILITY OF TRANSCUTANEOUS OXYGEN AND CARBON DIOXIDE PRESSURE MEASUREMENTS ASSOCIATED WITH SENSOR LOCATION.PULMONARY FUNCTION. VOL. 858. ISSUE . P. 39 -46 | 20 | 100% | 1 |
9 | RUIZ, Y , FARRERO, E , CORDOBA, A , GONZALEZ, N , DORCA, J , PRATS, E , (2016) TRANSCUTANEOUS CARBON DIOXIDE MONITORING IN SUBJECTS WITH ACUTE RESPIRATORY FAILURE AND SEVERE HYPERCAPNIA.RESPIRATORY CARE. VOL. 61. ISSUE 4. P. 428 -433 | 19 | 95% | 0 |
10 | URBANO, J , CRUZADO, V , LOPEZ-HERCE, J , DEL CASTILLO, J , BELLON, JM , CARRILLO, A , (2010) ACCURACY OF THREE TRANSCUTANEOUS CARBON DIOXIDE MONITORS IN CRITICALLY ILL CHILDREN.PEDIATRIC PULMONOLOGY. VOL. 45. ISSUE 5. P. 481-486 | 24 | 83% | 11 |
Classes with closest relation at Level 1 |