Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
3826 | 1900 | 30.3 | 69% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
0 | 4 | BIOCHEMISTRY & MOLECULAR BIOLOGY//CELL BIOLOGY//ONCOLOGY | 4064930 |
176 | 3 | DIABETES CARE//ENDOCRINOLOGY & METABOLISM//TYPE 2 DIABETES | 58057 |
79 | 2 | DIABETES CARE//DIABETES EDUCATOR//DIABETIC MEDICINE | 27337 |
3826 | 1 | DIABETES TECHNOLOGY & THERAPEUTICS//CONTINUOUS SUBCUTANEOUS INSULIN INFUSION//CSII | 1900 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | DIABETES TECHNOLOGY & THERAPEUTICS | journal | 1297546 | 17% | 25% | 329 |
2 | CONTINUOUS SUBCUTANEOUS INSULIN INFUSION | authKW | 1257156 | 6% | 66% | 119 |
3 | CSII | authKW | 1047755 | 5% | 72% | 91 |
4 | INSULIN PUMP | authKW | 1015063 | 6% | 54% | 116 |
5 | ARTIFICIAL PANCREAS | authKW | 918171 | 5% | 57% | 100 |
6 | INSULIN PUMP THERAPY | authKW | 644820 | 3% | 76% | 53 |
7 | CONTINUOUS GLUCOSE MONITORING | authKW | 569177 | 6% | 30% | 118 |
8 | DIABET TECHNOL | address | 368293 | 2% | 60% | 38 |
9 | MULTIPLE DAILY INJECTIONS | authKW | 277763 | 1% | 79% | 22 |
10 | INSULIN INFUSION SYSTEMS | authKW | 275736 | 2% | 55% | 31 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Endocrinology & Metabolism | 48267 | 61% | 0% | 1155 |
2 | Medical Informatics | 2080 | 4% | 0% | 80 |
3 | Engineering, Biomedical | 2038 | 9% | 0% | 165 |
4 | Pediatrics | 970 | 9% | 0% | 165 |
5 | Mathematical & Computational Biology | 588 | 4% | 0% | 67 |
6 | Computer Science, Interdisciplinary Applications | 315 | 4% | 0% | 78 |
7 | Automation & Control Systems | 267 | 3% | 0% | 54 |
8 | Medicine, General & Internal | 203 | 6% | 0% | 123 |
9 | Computer Science, Theory & Methods | 53 | 2% | 0% | 41 |
10 | Medical Laboratory Technology | 43 | 1% | 0% | 20 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | DIABET TECHNOL | 368293 | 2% | 60% | 38 |
2 | JESSE Z SARA LEA SHAFER ENDOCRINOL DIABE | 163503 | 2% | 31% | 33 |
3 | CHILDHOOD DIABET | 129349 | 2% | 22% | 37 |
4 | HAROLD NITZER DIABET HLTH | 100120 | 0% | 69% | 9 |
5 | UMC UNIV CHILDRENS HOSP | 72310 | 0% | 75% | 6 |
6 | INSERM CLIN INVEST 1411 | 64278 | 0% | 100% | 4 |
7 | DIRECNET COORDINATING | 60563 | 0% | 54% | 7 |
8 | DIABET MODELLING GRP | 52586 | 0% | 55% | 6 |
9 | BARBARA DAVIS CHILDHOOD DIABET | 48452 | 3% | 6% | 52 |
10 | COTE NACRE REG HOSP | 48208 | 0% | 100% | 3 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | DIABETES TECHNOLOGY & THERAPEUTICS | 1297546 | 17% | 25% | 329 |
2 | PEDIATRIC DIABETES | 80347 | 4% | 7% | 73 |
3 | DIABETES CARE | 55264 | 10% | 2% | 198 |
4 | DIABETIC MEDICINE | 19382 | 4% | 1% | 83 |
5 | DIABETES STOFFWECHSEL UND HERZ | 18397 | 1% | 7% | 17 |
6 | DIABETOLOGE | 14705 | 1% | 5% | 20 |
7 | DIABETOLOGIE UND STOFFWECHSEL | 13413 | 1% | 6% | 15 |
8 | ENDOCRINE PRACTICE | 10616 | 1% | 2% | 27 |
9 | DIABETES & METABOLISM | 9913 | 2% | 1% | 42 |
10 | DIABETES RESEARCH AND CLINICAL PRACTICE | 8138 | 3% | 1% | 52 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | CONTINUOUS SUBCUTANEOUS INSULIN INFUSION | 1257156 | 6% | 66% | 119 | Search CONTINUOUS+SUBCUTANEOUS+INSULIN+INFUSION | Search CONTINUOUS+SUBCUTANEOUS+INSULIN+INFUSION |
2 | CSII | 1047755 | 5% | 72% | 91 | Search CSII | Search CSII |
3 | INSULIN PUMP | 1015063 | 6% | 54% | 116 | Search INSULIN+PUMP | Search INSULIN+PUMP |
4 | ARTIFICIAL PANCREAS | 918171 | 5% | 57% | 100 | Search ARTIFICIAL+PANCREAS | Search ARTIFICIAL+PANCREAS |
5 | INSULIN PUMP THERAPY | 644820 | 3% | 76% | 53 | Search INSULIN+PUMP+THERAPY | Search INSULIN+PUMP+THERAPY |
6 | CONTINUOUS GLUCOSE MONITORING | 569177 | 6% | 30% | 118 | Search CONTINUOUS+GLUCOSE+MONITORING | Search CONTINUOUS+GLUCOSE+MONITORING |
7 | MULTIPLE DAILY INJECTIONS | 277763 | 1% | 79% | 22 | Search MULTIPLE+DAILY+INJECTIONS | Search MULTIPLE+DAILY+INJECTIONS |
8 | INSULIN INFUSION SYSTEMS | 275736 | 2% | 55% | 31 | Search INSULIN+INFUSION+SYSTEMS | Search INSULIN+INFUSION+SYSTEMS |
9 | BOLUS CALCULATOR | 149566 | 1% | 85% | 11 | Search BOLUS+CALCULATOR | Search BOLUS+CALCULATOR |
10 | TYPE 1 DIABETES | 135684 | 12% | 4% | 223 | Search TYPE+1+DIABETES | Search TYPE+1+DIABETES |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | POZZILLI, P , BATTELINO, T , DANNE, T , HOVORKA, R , JAROSZ-CHOBOT, P , RENARD, E , (2016) CONTINUOUS SUBCUTANEOUS INSULIN INFUSION IN DIABETES: PATIENT POPULATIONS, SAFETY, EFFICACY, AND PHARMACOECONOMICS.DIABETES-METABOLISM RESEARCH AND REVIEWS. VOL. 32. ISSUE 1. P. 21 -39 | 78 | 77% | 11 |
2 | TAUSCHMANN, M , HOVORKA, R , (2014) INSULIN PUMP THERAPY IN YOUTH WITH TYPE 1 DIABETES: TOWARD CLOSED-LOOP SYSTEMS.EXPERT OPINION ON DRUG DELIVERY. VOL. 11. ISSUE 6. P. 943 -955 | 77 | 79% | 4 |
3 | FORLENZA, GP , BUCKINGHAM, B , MAAHS, DM , (2016) PROGRESS IN DIABETES TECHNOLOGY: DEVELOPMENTS IN INSULIN PUMPS, CONTINUOUS GLUCOSE MONITORS, AND PROGRESS TOWARDS THE ARTIFICIAL PANCREAS.JOURNAL OF PEDIATRICS. VOL. 169. ISSUE . P. 13 -20 | 55 | 86% | 3 |
4 | BEQUETTE, BW , (2012) CHALLENGES AND RECENT PROGRESS IN THE DEVELOPMENT OF A CLOSED-LOOP ARTIFICIAL PANCREAS.ANNUAL REVIEWS IN CONTROL. VOL. 36. ISSUE 2. P. 255-266 | 54 | 92% | 42 |
5 | PETERS, AL , AHMANN, AJ , BATTELINO, T , EVERT, A , HIRSCH, IB , MURAD, MH , WINTER, WE , WOLPERT, H , (2016) DIABETES TECHNOLOGY-CONTINUOUS SUBCUTANEOUS INSULIN INFUSION THERAPY AND CONTINUOUS GLUCOSE MONITORING IN ADULTS: AN ENDOCRINE SOCIETY CLINICAL PRACTICE GUIDELINE.JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM. VOL. 101. ISSUE 11. P. 3922 -3937 | 62 | 71% | 1 |
6 | BATTELINO, T , OMLADIC, JS , PHILLIP, M , (2015) CLOSED LOOP INSULIN DELIVERY IN DIABETES.BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM. VOL. 29. ISSUE 3. P. 315 -325 | 51 | 78% | 8 |
7 | THABIT, H , HOVORKA, R , (2016) COMING OF AGE: THE ARTIFICIAL PANCREAS FOR TYPE 1 DIABETES.DIABETOLOGIA. VOL. 59. ISSUE 9. P. 1795 -1805 | 56 | 74% | 1 |
8 | BLAUW, H , KEITH-HYNES, P , KOOPS, R , DEVRIES, JH , (2016) A REVIEW OF SAFETY AND DESIGN REQUIREMENTS OF THE ARTIFICIAL PANCREAS.ANNALS OF BIOMEDICAL ENGINEERING. VOL. 44. ISSUE 11. P. 3158 -3172 | 48 | 92% | 0 |
9 | KROPFF, J , DEVRIES, JH , (2016) CONTINUOUS GLUCOSE MONITORING, FUTURE PRODUCTS, AND UPDATE ON WORLDWIDE ARTIFICIAL PANCREAS PROJECTS.DIABETES TECHNOLOGY & THERAPEUTICS. VOL. 18. ISSUE . P. 53 -63 | 34 | 100% | 4 |
10 | BRUTTOMESSO, D , COSTA, S , BARITUSSIO, A , (2009) CONTINUOUS SUBCUTANEOUS INSULIN INFUSION (CSII) 30 YEARS LATER: STILL THE BEST OPTION FOR INSULIN THERAPY.DIABETES-METABOLISM RESEARCH AND REVIEWS. VOL. 25. ISSUE 2. P. 99 -111 | 64 | 72% | 34 |
Classes with closest relation at Level 1 |