Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
35103 | 102 | 16.9 | 23% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
15 | 4 | MATHEMATICS//MATHEMATICS, APPLIED//MATH | 719832 |
94 | 3 | MATHEMATICS//MATHEMATICS, APPLIED//MATH | 76582 |
2349 | 2 | P HARMONIC MAPS//HARMONIC MAPS//GINZBURG LANDAU FUNCTIONAL | 4382 |
35103 | 1 | DUCT LEAKAGE//GAMMA2 CRITERION//CONICAL DIFFUSERS | 102 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | DUCT LEAKAGE | authKW | 1069172 | 5% | 71% | 5 |
2 | GAMMA2 CRITERION | authKW | 673578 | 3% | 75% | 3 |
3 | CONICAL DIFFUSERS | authKW | 598738 | 2% | 100% | 2 |
4 | OPENING DIFFUSER ANGLE | authKW | 598738 | 2% | 100% | 2 |
5 | GEPEA UMR6144CRTT | address | 399157 | 2% | 67% | 2 |
6 | STATIC PRESSURES | authKW | 399157 | 2% | 67% | 2 |
7 | 90 DEGREES ELBOW BEND | authKW | 299369 | 1% | 100% | 1 |
8 | AIR CONDITIONING OVERSIZING | authKW | 299369 | 1% | 100% | 1 |
9 | AIRFLOW INFILTRATION | authKW | 299369 | 1% | 100% | 1 |
10 | ALGEBRAIC MULTIGRID METHODAMG | authKW | 299369 | 1% | 100% | 1 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Construction & Building Technology | 7335 | 45% | 0% | 46 |
2 | Energy & Fuels | 1163 | 34% | 0% | 35 |
3 | Engineering, Civil | 1002 | 27% | 0% | 28 |
4 | Thermodynamics | 987 | 25% | 0% | 26 |
5 | Engineering, Mechanical | 952 | 31% | 0% | 32 |
6 | Engineering, Aerospace | 411 | 10% | 0% | 10 |
7 | Nuclear Science & Technology | 175 | 13% | 0% | 13 |
8 | Meteorology & Atmospheric Sciences | 35 | 6% | 0% | 6 |
9 | Engineering, Environmental | 30 | 5% | 0% | 5 |
10 | Engineering, Chemical | 25 | 8% | 0% | 8 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | GEPEA UMR6144CRTT | 399157 | 2% | 67% | 2 |
2 | DPT GENIE CIVIL BATIMENTECOLE TRAVAUX PUB | 299369 | 1% | 100% | 1 |
3 | ENERGETICSYST ENVIRONM | 299369 | 1% | 100% | 1 |
4 | FLIGHT TECHNOL CFD HIGH PERFORMANCE COMP | 299369 | 1% | 100% | 1 |
5 | GENERAT SYST | 299369 | 1% | 100% | 1 |
6 | GEPEAUMR6144ECOLE MINES NANTES | 299369 | 1% | 100% | 1 |
7 | SCI HABITATLASH | 299369 | 1% | 100% | 1 |
8 | THERMOFLUIDS ENERGY SYST | 299369 | 1% | 100% | 1 |
9 | EXPT NUMER THERMOFLOW | 149683 | 1% | 50% | 1 |
10 | IUT1 | 149683 | 1% | 50% | 1 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | HVAC&R RESEARCH | 45947 | 11% | 1% | 11 |
2 | JOURNAL OF ENERGY ENGINEERING-ASCE | 18703 | 4% | 2% | 4 |
3 | ENERGY AND BUILDINGS | 16502 | 19% | 0% | 19 |
4 | SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT | 12241 | 3% | 1% | 3 |
5 | ASHRAE JOURNAL | 10932 | 5% | 1% | 5 |
6 | JOURNAL OF APPLIED FLUID MECHANICS | 3601 | 3% | 0% | 3 |
7 | INTERNATIONAL JOURNAL OF ENERGY RESEARCH | 3480 | 6% | 0% | 6 |
8 | BUILDING SIMULATION | 3313 | 2% | 1% | 2 |
9 | JOURNAL OF ENGINEERING RESEARCH | 2007 | 1% | 1% | 1 |
10 | JOURNAL OF AIRCRAFT | 1282 | 5% | 0% | 5 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | DUCT LEAKAGE | 1069172 | 5% | 71% | 5 | Search DUCT+LEAKAGE | Search DUCT+LEAKAGE |
2 | GAMMA2 CRITERION | 673578 | 3% | 75% | 3 | Search GAMMA2+CRITERION | Search GAMMA2+CRITERION |
3 | CONICAL DIFFUSERS | 598738 | 2% | 100% | 2 | Search CONICAL+DIFFUSERS | Search CONICAL+DIFFUSERS |
4 | OPENING DIFFUSER ANGLE | 598738 | 2% | 100% | 2 | Search OPENING+DIFFUSER+ANGLE | Search OPENING+DIFFUSER+ANGLE |
5 | STATIC PRESSURES | 399157 | 2% | 67% | 2 | Search STATIC+PRESSURES | Search STATIC+PRESSURES |
6 | 90 DEGREES ELBOW BEND | 299369 | 1% | 100% | 1 | Search 90+DEGREES+ELBOW+BEND | Search 90+DEGREES+ELBOW+BEND |
7 | AIR CONDITIONING OVERSIZING | 299369 | 1% | 100% | 1 | Search AIR+CONDITIONING+OVERSIZING | Search AIR+CONDITIONING+OVERSIZING |
8 | AIRFLOW INFILTRATION | 299369 | 1% | 100% | 1 | Search AIRFLOW+INFILTRATION | Search AIRFLOW+INFILTRATION |
9 | ALGEBRAIC MULTIGRID METHODAMG | 299369 | 1% | 100% | 1 | Search ALGEBRAIC+MULTIGRID+METHODAMG | Search ALGEBRAIC+MULTIGRID+METHODAMG |
10 | BEOPT | 299369 | 1% | 100% | 1 | Search BEOPT | Search BEOPT |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | SALEHI, M , SLEITI, AK , IDEM, S , (2017) STUDY TO IDENTIFY COMPUTATIONAL FLUID DYNAMICS MODELS FOR USE IN DETERMINING HVAC DUCT FITTING LOSS COEFFICIENTS.SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT. VOL. 23. ISSUE 1. P. 181 -191 | 8 | 89% | 0 |
2 | KRISHNAMOORTHY, S , MODERA, M , (2016) IMPACTS OF DUCT LEAKAGE ON CENTRAL OUTDOOR-AIR CONDITIONING FOR COMMERCIAL-BUILDING VAV SYSTEMS.ENERGY AND BUILDINGS. VOL. 119. ISSUE . P. 340 -351 | 8 | 80% | 0 |
3 | CARRIE, FR , MODERA, MP , (2002) EXPERIMENTAL INVESTIGATION OF AEROSOL DEPOSITION ON SLOT- AND JOINT-TYPE LEAKS.JOURNAL OF AEROSOL SCIENCE. VOL. 33. ISSUE 10. P. 1447-1462 | 9 | 90% | 4 |
4 | MOUJAES, S , GUNDAVELLI, R , (2012) CFD SIMULATION OF LEAK IN RESIDENTIAL HVAC DUCTS.ENERGY AND BUILDINGS. VOL. 54. ISSUE . P. 534-539 | 5 | 83% | 3 |
5 | MUMMA, SA , MAHANK, TA , KE, YP , (1998) ANALYTICAL DETERMINATION OF DUCT FITTING LOSS-COEFFICIENTS.APPLIED ENERGY. VOL. 61. ISSUE 4. P. 229 -247 | 5 | 100% | 7 |
6 | KULKARNI, D , IDEM, S , (2017) ENERGY BALANCE ANALYSIS OF HVAC DIVIDED FLOW FITTINGS.SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT. VOL. 23. ISSUE 1. P. 218 -225 | 3 | 100% | 0 |
7 | FAZLI, T , YEAP, RY , STEPHENS, B , (2015) MODELING THE ENERGY AND COST IMPACTS OF EXCESS STATIC PRESSURE IN CENTRAL FORCED-AIR HEATING AND AIR-CONDITIONING SYSTEMS IN SINGLE-FAMILY RESIDENCES IN THE US.ENERGY AND BUILDINGS. VOL. 107. ISSUE . P. 243 -253 | 5 | 63% | 0 |
8 | STEPHENS, B , (2014) THE IMPACTS OF DUCT DESIGN ON LIFE CYCLE COSTS OF CENTRAL RESIDENTIAL HEATING AND AIR-CONDITIONING SYSTEMS.ENERGY AND BUILDINGS. VOL. 82. ISSUE . P. 563 -579 | 5 | 63% | 0 |
9 | MODERA, MP , BRZOZOWSKI, O , CARRIE, FR , DICKERHOFF, DJ , DELP, WW , FISK, WJ , LEVINSON, R , WANG, D , (2002) SEALING DUCTS IN LARGE COMMERCIAL BUILDINGS WITH AEROSOLIZED SEALANT PARTICLES.ENERGY AND BUILDINGS. VOL. 34. ISSUE 7. P. 705-714 | 4 | 100% | 5 |
10 | CARRIE, FR , MODERA, MP , (1998) PARTICLE DEPOSITION IN A TWO-DIMENSIONAL SLOT FROM A TRANSVERSE STREAM.AEROSOL SCIENCE AND TECHNOLOGY. VOL. 28. ISSUE 3. P. 235-246 | 4 | 100% | 1 |
Classes with closest relation at Level 1 |