Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
31177 | 157 | 16.1 | 47% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
5 | 4 | CHEMISTRY, ORGANIC//CHEMISTRY, INORGANIC & NUCLEAR//CHEMISTRY, MULTIDISCIPLINARY | 1745167 |
189 | 3 | JOURNAL OF MAGNETIC RESONANCE//MAGNETIC RESONANCE IN MEDICINE//JOURNAL OF BIOMOLECULAR NMR | 54843 |
1170 | 2 | JOURNAL OF MAGNETIC RESONANCE//GRADIENT COIL//RESTRICTED DIFFUSION | 9352 |
31177 | 1 | PULSE PROGRAMMER//MRI SIMULATION//PULSE SEQUENCE GENERATION | 157 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | PULSE PROGRAMMER | authKW | 622378 | 3% | 80% | 4 |
2 | MRI SIMULATION | authKW | 529447 | 4% | 39% | 7 |
3 | PULSE SEQUENCE GENERATION | authKW | 388987 | 1% | 100% | 2 |
4 | SEQUENCE PROGRAMMING | authKW | 388987 | 1% | 100% | 2 |
5 | SUBSTITUTED DIHYDRONAPHTHALENES | authKW | 388987 | 1% | 100% | 2 |
6 | INTRA VOXEL DEPHASING | authKW | 259324 | 1% | 67% | 2 |
7 | CEREBRAL VASCULATURE MODELING | authKW | 194494 | 1% | 100% | 1 |
8 | COMPUTER PROGRAMM | authKW | 194494 | 1% | 100% | 1 |
9 | CPDL | authKW | 194494 | 1% | 100% | 1 |
10 | CREATISUMR 5515U630INSA LYON | address | 194494 | 1% | 100% | 1 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Instruments & Instrumentation | 3105 | 44% | 0% | 69 |
2 | Spectroscopy | 1135 | 24% | 0% | 37 |
3 | Physics, Atomic, Molecular & Chemical | 658 | 26% | 0% | 41 |
4 | Physics, Applied | 419 | 34% | 0% | 54 |
5 | Radiology, Nuclear Medicine & Medical Imaging | 326 | 18% | 0% | 29 |
6 | Biochemical Research Methods | 303 | 15% | 0% | 24 |
7 | Engineering, General | 75 | 6% | 0% | 9 |
8 | Computer Science, Interdisciplinary Applications | 43 | 5% | 0% | 8 |
9 | Engineering, Biomedical | 38 | 4% | 0% | 7 |
10 | Imaging Science & Photographic Technology | 23 | 2% | 0% | 3 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | CREATISUMR 5515U630INSA LYON | 194494 | 1% | 100% | 1 |
2 | CREATISUMR CNRS 5520 | 194494 | 1% | 100% | 1 |
3 | FDN MONDINO NMR | 194494 | 1% | 100% | 1 |
4 | H IM MR PLM AW ORTHOPED | 194494 | 1% | 100% | 1 |
5 | NIH GRC 4D08 | 194494 | 1% | 100% | 1 |
6 | THEORET RADIO ENGN RADIOMETR | 194494 | 1% | 100% | 1 |
7 | RIL | 97246 | 1% | 50% | 1 |
8 | RADIO ENGN INFORMAT SECUR | 64830 | 1% | 33% | 1 |
9 | HOSP LUND | 48622 | 1% | 25% | 1 |
10 | MICHAEL STIFEL DATA DRIVEN SIMULAT SCI JENA | 38897 | 1% | 20% | 1 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | REVIEW OF SCIENTIFIC INSTRUMENTS | 17549 | 33% | 0% | 52 |
2 | JOURNAL OF MAGNETIC RESONANCE | 12504 | 15% | 0% | 24 |
3 | CONCEPTS IN MAGNETIC RESONANCE | 9773 | 2% | 2% | 3 |
4 | MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE | 7236 | 4% | 1% | 6 |
5 | CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING | 6093 | 2% | 1% | 3 |
6 | COMPUTERS & CHEMISTRY | 3174 | 3% | 0% | 4 |
7 | JOURNAL OF MAGNETIC RESONANCE SERIES A | 3037 | 3% | 0% | 4 |
8 | MAGNETIC RESONANCE IN MEDICAL SCIENCES | 2375 | 1% | 1% | 2 |
9 | MEASUREMENT SCIENCE AND TECHNOLOGY | 1362 | 5% | 0% | 8 |
10 | JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS | 1353 | 3% | 0% | 4 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | PULSE PROGRAMMER | 622378 | 3% | 80% | 4 | Search PULSE+PROGRAMMER | Search PULSE+PROGRAMMER |
2 | MRI SIMULATION | 529447 | 4% | 39% | 7 | Search MRI+SIMULATION | Search MRI+SIMULATION |
3 | PULSE SEQUENCE GENERATION | 388987 | 1% | 100% | 2 | Search PULSE+SEQUENCE+GENERATION | Search PULSE+SEQUENCE+GENERATION |
4 | SEQUENCE PROGRAMMING | 388987 | 1% | 100% | 2 | Search SEQUENCE+PROGRAMMING | Search SEQUENCE+PROGRAMMING |
5 | SUBSTITUTED DIHYDRONAPHTHALENES | 388987 | 1% | 100% | 2 | Search SUBSTITUTED+DIHYDRONAPHTHALENES | Search SUBSTITUTED+DIHYDRONAPHTHALENES |
6 | INTRA VOXEL DEPHASING | 259324 | 1% | 67% | 2 | Search INTRA+VOXEL+DEPHASING | Search INTRA+VOXEL+DEPHASING |
7 | CEREBRAL VASCULATURE MODELING | 194494 | 1% | 100% | 1 | Search CEREBRAL+VASCULATURE+MODELING | Search CEREBRAL+VASCULATURE+MODELING |
8 | COMPUTER PROGRAMM | 194494 | 1% | 100% | 1 | Search COMPUTER+PROGRAMM | Search COMPUTER+PROGRAMM |
9 | CPDL | 194494 | 1% | 100% | 1 | Search CPDL | Search CPDL |
10 | DEOXYHEMIGOSSYPOL | 194494 | 1% | 100% | 1 | Search DEOXYHEMIGOSSYPOL | Search DEOXYHEMIGOSSYPOL |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | TANG, WN , SUN, HY , WANG, WM , (2012) A DIGITAL RECEIVER MODULE WITH DIRECT DATA ACQUISITION FOR MAGNETIC RESONANCE IMAGING SYSTEMS.REVIEW OF SCIENTIFIC INSTRUMENTS. VOL. 83. ISSUE 10. P. - | 13 | 93% | 5 |
2 | XIAO, L , LI, L , NIE, W , XIE, XM , WAN, HJ , (2015) A DIGITAL SIGNAL PROCESSOR-BASED PULSE PROGRAMMER WITH PERFORMANCE OF RUN-TIME INFORMATION HANDLING FOR MAGNETIC RESONANCE IMAGING.MEASUREMENT SCIENCE AND TECHNOLOGY. VOL. 26. ISSUE 6. P. - | 12 | 75% | 0 |
3 | MAO, WP , BAO, QJ , YANG, LA , CHEN, YQ , LIU, CY , QIU, JQ , YE, CH , (2011) A MODULARIZED PULSE PROGRAMMER FOR NMR SPECTROSCOPY.MEASUREMENT SCIENCE AND TECHNOLOGY. VOL. 22. ISSUE 2. P. - | 17 | 55% | 5 |
4 | PIKULSKI, M , SHIROKA, T , OTT, HR , MESOT, J , (2014) A FIRMWARE-DEFINED DIGITAL DIRECT-SAMPLING NMR SPECTROMETER FOR CONDENSED MATTER PHYSICS.REVIEW OF SCIENTIFIC INSTRUMENTS. VOL. 85. ISSUE 9. P. - | 13 | 65% | 2 |
5 | LIANG, X , TANG, X , TANG, WN , GAO, JH , (2014) A HIGH-FIELD MAGNETIC RESONANCE IMAGING SPECTROMETER USING AN OVEN-CONTROLLED CRYSTAL OSCILLATOR AS THE LOCAL OSCILLATOR OF ITS RADIO FREQUENCY TRANSCEIVER.REVIEW OF SCIENTIFIC INSTRUMENTS. VOL. 85. ISSUE 9. P. - | 12 | 67% | 1 |
6 | XIAO, L , SUN, BH , MA, YP , ZHAO, RY , (2013) A DIGITAL MAGNETIC RESONANCE IMAGING SPECTROMETER USING DIGITAL SIGNAL PROCESSOR AND FIELD PROGRAMMABLE GATE ARRAY.REVIEW OF SCIENTIFIC INSTRUMENTS. VOL. 84. ISSUE 5. P. - | 10 | 77% | 4 |
7 | HASHIMOTO, S , KOSE, K , HAISHI, T , (2014) COMPARISON OF ANALOG AND DIGITAL TRANSCEIVER SYSTEMS FOR MR IMAGING.MAGNETIC RESONANCE IN MEDICAL SCIENCES. VOL. 13. ISSUE 4. P. 285 -291 | 11 | 69% | 0 |
8 | TSUDA, M , TAMADA, D , TERADA, Y , KOSE, K , (2016) DEVELOPMENT OF DIGITAL MRI CONSOLES USING GENERAL-PURPOSE DIGITAL INSTRUMENTS AND MICROCONTROLLER BOARDS.APPLIED MAGNETIC RESONANCE. VOL. 47. ISSUE 8. P. 847 -858 | 7 | 100% | 0 |
9 | SHARP, JC , YIN, DY , BERNHARDT, RH , DENG, QL , PROCCA, AE , TYSON, RL , LO, K , TOMANEK, B , (2009) THE INTEGRATION OF REAL AND VIRTUAL MAGNETIC RESONANCE IMAGING EXPERIMENTS IN A SINGLE INSTRUMENT.REVIEW OF SCIENTIFIC INSTRUMENTS. VOL. 80. ISSUE 9. P. - | 12 | 67% | 0 |
10 | TANG, WN , WANG, WM , (2011) A SINGLE-BOARD NMR SPECTROMETER BASED ON A SOFTWARE DEFINED RADIO ARCHITECTURE.MEASUREMENT SCIENCE AND TECHNOLOGY. VOL. 22. ISSUE 1. P. - | 10 | 71% | 7 |
Classes with closest relation at Level 1 |