Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
23474 | 345 | 16.8 | 52% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | MAGNETIC INDUCTION TOMOGRAPHY | authKW | 5958739 | 21% | 94% | 72 |
2 | MAGNETIC INDUCTION TOMOGRAPHY MIT | authKW | 804613 | 3% | 91% | 10 |
3 | ELECTROMAGNETIC INDUCTION TOMOGRAPHY | authKW | 442538 | 1% | 100% | 5 |
4 | INDUCTIVE IMAGING | authKW | 442538 | 1% | 100% | 5 |
5 | ELECTRIC FIELD TOMOGRAPHY | authKW | 354031 | 1% | 100% | 4 |
6 | MAGNETIC INDUCTION MEASUREMENT | authKW | 265523 | 1% | 100% | 3 |
7 | NUCL SECUR PROGRAMME | address | 265523 | 1% | 100% | 3 |
8 | RADIO IMAGING METHOD | authKW | 265523 | 1% | 100% | 3 |
9 | ELECTROMAGNETIC TOMOGRAPHY | authKW | 245080 | 3% | 23% | 12 |
10 | ELECTROMAGNETIC INDUCTANCE TOMOGRAPHY | authKW | 199141 | 1% | 75% | 3 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Engineering, Biomedical | 3853 | 27% | 0% | 92 |
2 | Materials Science, Characterization, Testing | 1970 | 10% | 0% | 33 |
3 | Instruments & Instrumentation | 1826 | 23% | 0% | 80 |
4 | Engineering, General | 749 | 12% | 0% | 40 |
5 | Engineering, Electrical & Electronic | 736 | 28% | 0% | 98 |
6 | Physiology | 653 | 16% | 0% | 54 |
7 | Biophysics | 608 | 16% | 0% | 55 |
8 | Medical Informatics | 254 | 3% | 0% | 12 |
9 | Computer Science, Interdisciplinary Applications | 176 | 7% | 0% | 23 |
10 | Telecommunications | 105 | 5% | 0% | 18 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | NUCL SECUR PROGRAMME | 265523 | 1% | 100% | 3 |
2 | NOVEL DETECT CONCEPTS | 177015 | 1% | 100% | 2 |
3 | SENSING IMAGING SIGNAL PROC GRP | 128733 | 1% | 36% | 4 |
4 | FUNDAMENTALS THEORY ELECT ENGN | 100333 | 3% | 9% | 12 |
5 | CIENCIAS COMPUTAC IIMAS | 88508 | 0% | 100% | 1 |
6 | CORUS RD T TEESSIDE TECHNOL | 88508 | 0% | 100% | 1 |
7 | DIAGNOST NONDESTRUCT TESTING SIGNAL PROC | 88508 | 0% | 100% | 1 |
8 | ELEC ELECT COMP ENGN | 88508 | 0% | 100% | 1 |
9 | ELEC TELECOMUNICACOES | 88508 | 0% | 100% | 1 |
10 | EMGS EMM FAM | 88508 | 0% | 100% | 1 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | PHYSIOLOGICAL MEASUREMENT | 95445 | 15% | 2% | 53 |
2 | MEASUREMENT SCIENCE AND TECHNOLOGY | 10606 | 10% | 0% | 33 |
3 | INSIGHT | 4975 | 3% | 1% | 9 |
4 | RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING | 4705 | 3% | 1% | 9 |
5 | NDT & E INTERNATIONAL | 3168 | 2% | 0% | 8 |
6 | PRZEGLAD ELEKTROTECHNICZNY | 3029 | 3% | 0% | 11 |
7 | NONDESTRUCTIVE TESTING AND EVALUATION | 2779 | 1% | 1% | 3 |
8 | FLOW MEASUREMENT AND INSTRUMENTATION | 2639 | 2% | 0% | 6 |
9 | COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING | 2264 | 2% | 0% | 8 |
10 | TM-TECHNISCHES MESSEN | 2027 | 1% | 1% | 4 |
Author Key Words |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | ZAKARIA, Z , RAHIM, RA , MANSOR, MSB , YAACOB, S , AYOB, NMN , RAHIMAN, MHF , AMAN, SMKS , MUJI, SZM , (2012) ADVANCEMENTS IN TRANSMITTERS AND SENSORS FOR BIOLOGICAL TISSUE IMAGING IN MAGNETIC INDUCTION TOMOGRAPHY.SENSORS. VOL. 12. ISSUE 6. P. 7126 -7156 | 45 | 70% | 9 |
2 | GURSOY, D , SCHARFETTER, H , (2011) IMAGING ARTIFACTS IN MAGNETIC INDUCTION TOMOGRAPHY CAUSED BY THE STRUCTURAL INCORRECTNESS OF THE SENSOR MODEL.MEASUREMENT SCIENCE AND TECHNOLOGY. VOL. 22. ISSUE 1. P. - | 26 | 96% | 4 |
3 | WEI, HY , SOLEIMANI, M , (2012) HARDWARE AND SOFTWARE DESIGN FOR A NATIONAL INSTRUMENT-BASED MAGNETIC INDUCTION TOMOGRAPHY SYSTEM FOR PROSPECTIVE BIOMEDICAL APPLICATIONS.PHYSIOLOGICAL MEASUREMENT. VOL. 33. ISSUE 5. P. 863-879 | 19 | 86% | 11 |
4 | FU, Y , TAN, C , DONG, F , (2016) ANALYSIS OF RESPONSE FOR MAGNETIC INDUCTION TOMOGRAPHY WITH INTERNAL SOURCE.MEASUREMENT. VOL. 78. ISSUE . P. 260 -277 | 19 | 73% | 0 |
5 | YANG, TM , CHEN, G , YIN, WL , HU, PP , ZHAO, Q , (2014) A HIGH FREQUENCY DIGITAL INDUCTION SYSTEM FOR CONDUTIVE FLOW LEVEL MEASUREMENTS.FLOW MEASUREMENT AND INSTRUMENTATION. VOL. 37. ISSUE . P. 83-91 | 17 | 81% | 2 |
6 | MA, L , HUNT, A , SOLEIMANI, M , (2015) EXPERIMENTAL EVALUATION OF CONDUCTIVE FLOW IMAGING USING MAGNETIC INDUCTION TOMOGRAPHY.INTERNATIONAL JOURNAL OF MULTIPHASE FLOW. VOL. 72. ISSUE . P. 198 -209 | 18 | 72% | 2 |
7 | WEI, HY , WILKINSON, AJ , (2011) DESIGN OF A SENSOR COIL AND MEASUREMENT ELECTRONICS FOR MAGNETIC INDUCTION TOMOGRAPHY.IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. VOL. 60. ISSUE 12. P. 3853-3859 | 14 | 100% | 9 |
8 | SCHARFETTER, H , HOLLAUS, K , ROSELL-FERRER, J , MERWA, R , (2006) SINGLE-STEP 3-D IMAGE RECONSTRUCTION IN MAGNETIC INDUCTION TOMOGRAPHY: THEORETICAL LIMITS OF SPATIAL RESOLUTION AND CONTRAST TO NOISE RATIO.ANNALS OF BIOMEDICAL ENGINEERING. VOL. 34. ISSUE 11. P. 1786 -1798 | 20 | 80% | 15 |
9 | MA, L , SOLEIMANI, M , (2012) LIMITED ANGLE AND LIMITED DATA ELECTROMAGNETIC INDUCTION TOMOGRAPHY: EXPERIMENTAL EVALUATION OF THE EFFECT OF MISSING DATA.MEASUREMENT SCIENCE AND TECHNOLOGY. VOL. 23. ISSUE 12. P. - | 14 | 100% | 0 |
10 | MA, L , SOLEIMANI, M , (2014) HIDDEN DEFECT IDENTIFICATION IN CARBON FIBRE REINFORCED POLYMER PLATES USING MAGNETIC INDUCTION TOMOGRAPHY.MEASUREMENT SCIENCE AND TECHNOLOGY. VOL. 25. ISSUE 5. P. - | 21 | 60% | 2 |
Classes with closest relation at Level 1 |