Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
19769 | 490 | 23.6 | 71% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
6 | 4 | GASTROENTEROLOGY & HEPATOLOGY//ONCOLOGY//SURGERY | 1371034 |
174 | 3 | RADIAT ONCOL//MEDICAL PHYSICS//HEAD AND NECK CANCER | 58342 |
194 | 2 | MEDICAL PHYSICS//PHYSICS IN MEDICINE AND BIOLOGY//RADIAT ONCOL | 21467 |
19769 | 1 | LINAC MR//MRI LINAC//MR LINAC | 490 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | LINAC MR | authKW | 527846 | 2% | 71% | 12 |
2 | MRI LINAC | authKW | 508902 | 3% | 58% | 14 |
3 | MR LINAC | authKW | 336499 | 2% | 60% | 9 |
4 | GEOMETRIC DISTORTION | authKW | 326514 | 5% | 20% | 26 |
5 | MRIGRT | authKW | 311580 | 1% | 100% | 5 |
6 | 3D PHANTOM | authKW | 259648 | 1% | 83% | 5 |
7 | SYNTHETIC CT | authKW | 259648 | 1% | 83% | 5 |
8 | COMPUTED TOMOGRAPHY SUBSTITUTE | authKW | 249264 | 1% | 100% | 4 |
9 | PSEUDO CT | authKW | 249260 | 1% | 67% | 6 |
10 | MRI GUIDED RADIOTHERAPY | authKW | 234877 | 1% | 54% | 7 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Radiology, Nuclear Medicine & Medical Imaging | 23521 | 83% | 0% | 409 |
2 | Engineering, Biomedical | 3031 | 20% | 0% | 98 |
3 | Oncology | 814 | 22% | 0% | 110 |
4 | Neuroimaging | 37 | 1% | 0% | 6 |
5 | Imaging Science & Photographic Technology | 10 | 1% | 0% | 4 |
6 | Clinical Neurology | 5 | 3% | 0% | 15 |
7 | Computer Science, Interdisciplinary Applications | 4 | 1% | 0% | 7 |
8 | Physics, Nuclear | 3 | 2% | 0% | 8 |
9 | Surgery | 3 | 4% | 0% | 19 |
10 | Nuclear Science & Technology | 2 | 1% | 0% | 7 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | RADIAT PHYS SECT | 142433 | 1% | 57% | 4 |
2 | AKH 3B | 62316 | 0% | 100% | 1 |
3 | AUSTIN HLTH RADIAT ONCOL | 62316 | 0% | 100% | 1 |
4 | COMMONWEALTH SCI IND ORG COMPUTAT INFORMAT | 62316 | 0% | 100% | 1 |
5 | CORE IL EXPT MRIS 7 T | 62316 | 0% | 100% | 1 |
6 | DIAG INTERVENT NEURORADIOL | 62316 | 0% | 100% | 1 |
7 | EA 5041 | 62316 | 0% | 100% | 1 |
8 | EPILEPSY RADIOSURG PROGRAM | 62316 | 0% | 100% | 1 |
9 | FEDERATIF RECH GENET FONCT AGRON SANTE 14 | 62316 | 0% | 100% | 1 |
10 | FUNCT IMAGING IZOPHRENIA TESTBED BIOMED INFORM | 62316 | 0% | 100% | 1 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | MEDICAL PHYSICS | 68285 | 23% | 1% | 111 |
2 | PHYSICS IN MEDICINE AND BIOLOGY | 36701 | 16% | 1% | 80 |
3 | MAGNETIC RESONANCE IMAGING | 8434 | 5% | 1% | 25 |
4 | SEMINARS IN RADIATION ONCOLOGY | 7839 | 2% | 1% | 10 |
5 | RADIATION ONCOLOGY | 5911 | 3% | 1% | 13 |
6 | JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 5415 | 2% | 1% | 11 |
7 | RADIOTHERAPY AND ONCOLOGY | 5050 | 4% | 0% | 22 |
8 | INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 4143 | 7% | 0% | 34 |
9 | BRITISH JOURNAL OF RADIOLOGY | 3746 | 4% | 0% | 22 |
10 | AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE | 1974 | 1% | 1% | 4 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | LINAC MR | 527846 | 2% | 71% | 12 | Search LINAC+MR | Search LINAC+MR |
2 | MRI LINAC | 508902 | 3% | 58% | 14 | Search MRI+LINAC | Search MRI+LINAC |
3 | MR LINAC | 336499 | 2% | 60% | 9 | Search MR+LINAC | Search MR+LINAC |
4 | GEOMETRIC DISTORTION | 326514 | 5% | 20% | 26 | Search GEOMETRIC+DISTORTION | Search GEOMETRIC+DISTORTION |
5 | MRIGRT | 311580 | 1% | 100% | 5 | Search MRIGRT | Search MRIGRT |
6 | 3D PHANTOM | 259648 | 1% | 83% | 5 | Search 3D+PHANTOM | Search 3D+PHANTOM |
7 | SYNTHETIC CT | 259648 | 1% | 83% | 5 | Search SYNTHETIC+CT | Search SYNTHETIC+CT |
8 | COMPUTED TOMOGRAPHY SUBSTITUTE | 249264 | 1% | 100% | 4 | Search COMPUTED+TOMOGRAPHY+SUBSTITUTE | Search COMPUTED+TOMOGRAPHY+SUBSTITUTE |
9 | PSEUDO CT | 249260 | 1% | 67% | 6 | Search PSEUDO+CT | Search PSEUDO+CT |
10 | MRI GUIDED RADIOTHERAPY | 234877 | 1% | 54% | 7 | Search MRI+GUIDED+RADIOTHERAPY | Search MRI+GUIDED+RADIOTHERAPY |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | OBORN, BM , GE, Y , HARDCASTLE, N , METCALFE, PE , KEALL, PJ , (2016) DOSE ENHANCEMENT IN RADIOTHERAPY OF SMALL LUNG TUMORS USING INLINE MAGNETIC FIELDS: A MONTE CARLO BASED PLANNING STUDY.MEDICAL PHYSICS. VOL. 43. ISSUE 1. P. 368 -377 | 36 | 92% | 3 |
2 | PRIOR, P , CHEN, XF , BOTROS, M , PAULSON, ES , LAWTON, C , ERICKSON, B , LI, XA , (2016) MRI-BASED IMRT PLANNING FOR MR-LINAC: COMPARISON BETWEEN CT- AND MRI-BASED PLANS FOR PANCREATIC AND PROSTATE CANCERS.PHYSICS IN MEDICINE AND BIOLOGY. VOL. 61. ISSUE 10. P. 3819 -3842 | 37 | 95% | 0 |
3 | OBORN, BM , DOWDELL, S , METCALFE, PE , CROZIER, S , MOHAN, R , KEALL, PJ , (2015) PROTON BEAM DEFLECTION IN MRI FIELDS: IMPLICATIONS FOR MRI-GUIDED PROTON THERAPY.MEDICAL PHYSICS. VOL. 42. ISSUE 5. P. 2113 -2124 | 32 | 74% | 1 |
4 | PRICE, RG , KADBI, M , KIM, J , BAITER, J , CHETTY, IJ , GLIDE-HURST, CK , (2015) TECHNICAL NOTE: CHARACTERIZATION AND CORRECTION OF GRADIENT NONLINEARITY INDUCED DISTORTION ON A 1.0 T OPEN BORE MR-SIM.MEDICAL PHYSICS. VOL. 42. ISSUE 10. P. 5955 -5960 | 25 | 89% | 1 |
5 | EDMUND, JM , NYHOLM, T , (2017) A REVIEW OF SUBSTITUTE CT GENERATION FOR MRI-ONLY RADIATION THERAPY.RADIATION ONCOLOGY. VOL. 12. ISSUE . P. - | 39 | 51% | 0 |
6 | NYHOLM, T , JONSSON, J , (2014) COUNTERPOINT: OPPORTUNITIES AND CHALLENGES OF A MAGNETIC RESONANCE IMAGING-ONLY RADIOTHERAPY WORK FLOW.SEMINARS IN RADIATION ONCOLOGY. VOL. 24. ISSUE 3. P. 175 -180 | 24 | 77% | 9 |
7 | WALKER, A , LINEY, G , METCALFE, P , HOLLOWAY, L , (2014) MRI DISTORTION: CONSIDERATIONS FOR MRI BASED RADIOTHERAPY TREATMENT PLANNING.AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE. VOL. 37. ISSUE 1. P. 103-113 | 19 | 95% | 9 |
8 | PARADIS, E , CAO, Y , LAWRENCE, TS , TSIEN, C , FENG, M , VINEBERG, K , BALTER, JM , (2015) ASSESSING THE DOSIMETRIC ACCURACY OF MAGNETIC RESONANCE-GENERATED SYNTHETIC CT IMAGES FOR FOCAL BRAIN VMAT RADIATION THERAPY.INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS. VOL. 93. ISSUE 5. P. 1154 -1161 | 25 | 74% | 1 |
9 | WEYGAND, J , FULLER, CD , IBBOTT, GS , MOHAMED, ASR , DING, Y , YANG, JZ , HWANG, KP , WANG, JH , (2016) SPATIAL PRECISION IN MAGNETIC RESONANCE IMAGING-GUIDED RADIATION THERAPY: THE ROLE OF GEOMETRIC DISTORTION.INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS. VOL. 95. ISSUE 4. P. 1304 -1316 | 41 | 41% | 1 |
10 | KIM, J , GLIDE-HURST, C , DOEMER, A , WEN, N , MOVSAS, B , CHETTY, IJ , (2015) IMPLEMENTATION OF A NOVEL ALGORITHM FOR GENERATING SYNTHETIC CT IMAGES FROM MAGNETIC RESONANCE IMAGING DATA SETS FOR PROSTATE CANCER RADIATION THERAPY.INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS. VOL. 91. ISSUE 1. P. 39 -47 | 23 | 70% | 8 |
Classes with closest relation at Level 1 |