Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
17479 | 597 | 20.2 | 54% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
8 | 4 | CARDIAC & CARDIOVASCULAR SYSTEM//PERIPHERAL VASCULAR DISEASES//CARDIOL | 1276458 |
312 | 3 | ARTERIAL STIFFNESS//HEART RATE VARIABILITY//SYNCOPE | 40088 |
634 | 2 | ARTERIAL STIFFNESS//PULSE WAVE VELOCITY//BLOOD PRESSURE MONITORING | 13752 |
17479 | 1 | FINAPRES//T LINE//MEASUREMENT TECHNIQUES BLOOD PRESSURE | 597 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | FINAPRES | authKW | 443237 | 4% | 33% | 26 |
2 | T LINE | authKW | 306881 | 1% | 100% | 6 |
3 | MEASUREMENT TECHNIQUES BLOOD PRESSURE | authKW | 250615 | 1% | 70% | 7 |
4 | VOLUME COMPENSATION METHOD | authKW | 163668 | 1% | 80% | 4 |
5 | NONINVASIVE BLOOD PRESSURE | authKW | 159820 | 2% | 31% | 10 |
6 | BEAT TO BEAT ARTERIAL COMPLIANCE | authKW | 153440 | 1% | 100% | 3 |
7 | CATHETER TRANSDUCER SYSTEMS | authKW | 153440 | 1% | 100% | 3 |
8 | FAST FLUSH TEST | authKW | 153440 | 1% | 100% | 3 |
9 | INSTANTANEOUS ARTERIAL BLOOD PRESSURE | authKW | 153440 | 1% | 100% | 3 |
10 | VASCULAR UNLOADING TECHNIQUE | authKW | 153440 | 1% | 100% | 3 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Anesthesiology | 21097 | 36% | 0% | 213 |
2 | Medical Informatics | 3378 | 9% | 0% | 56 |
3 | Engineering, Biomedical | 2666 | 17% | 0% | 102 |
4 | Critical Care Medicine | 1448 | 10% | 0% | 59 |
5 | Peripheral Vascular Diseases | 783 | 11% | 0% | 67 |
6 | Mathematical & Computational Biology | 734 | 7% | 0% | 40 |
7 | Physiology | 351 | 9% | 0% | 55 |
8 | Computer Science, Interdisciplinary Applications | 307 | 7% | 0% | 40 |
9 | Cardiac & Cardiovascular System | 145 | 7% | 0% | 44 |
10 | MEDICINE, MISCELLANEOUS | 126 | 0% | 0% | 2 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | TPD BIOMED RUMENTAT | 68194 | 0% | 67% | 2 |
2 | CARDIO VASC ANESTHESIA POST SURG INTENS CARE UN | 51147 | 0% | 100% | 1 |
3 | CARDIOVASC TELEMETRY UNIT | 51147 | 0% | 100% | 1 |
4 | CLIN PHYSIOL ISOTOPE MED | 51147 | 0% | 100% | 1 |
5 | CNRSTIMC PRETA | 51147 | 0% | 100% | 1 |
6 | CNRSURA 1482 | 51147 | 0% | 100% | 1 |
7 | HLTH SCIAZIENDA OSPEDUNIV CAREGGI | 51147 | 0% | 100% | 1 |
8 | HOP EACH | 51147 | 0% | 100% | 1 |
9 | INNOVATISVE PROD TECHNOL | 51147 | 0% | 100% | 1 |
10 | IRCCS FDN DON CARLO GNOCCHI | 51147 | 0% | 100% | 1 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | JOURNAL OF CLINICAL MONITORING | 81006 | 5% | 6% | 27 |
2 | JOURNAL OF CLINICAL MONITORING AND COMPUTING | 24099 | 3% | 2% | 19 |
3 | BLOOD PRESSURE MONITORING | 22055 | 3% | 2% | 20 |
4 | MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING | 16031 | 6% | 1% | 37 |
5 | HOMEOSTASIS IN HEALTH AND DISEASE | 10896 | 1% | 3% | 8 |
6 | MEDICAL INSTRUMENTATION | 10788 | 1% | 3% | 8 |
7 | BRITISH JOURNAL OF ANAESTHESIA | 4734 | 5% | 0% | 29 |
8 | ANESTHESIOLOGY | 4064 | 5% | 0% | 30 |
9 | PHYSIOLOGICAL MEASUREMENT | 3825 | 2% | 1% | 14 |
10 | CLINICAL PHYSIOLOGY | 3275 | 2% | 1% | 9 |
Author Key Words |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | KIM, SH , LILOT, M , SIDHU, KS , RINEHART, J , YU, ZX , CANALES, C , CANNESSON, M , (2014) ACCURACY AND PRECISION OF CONTINUOUS NONINVASIVE ARTERIAL PRESSURE MONITORING COMPARED WITH INVASIVE ARTERIAL PRESSURE A SYSTEMATIC REVIEW AND META-ANALYSIS.ANESTHESIOLOGY. VOL. 120. ISSUE 5. P. 1080-1097 | 34 | 63% | 21 |
2 | WIELING, W , VAN MONTFRANS, GA , WESSELING, KH , IMHOLZ, BPM , (1998) FIFTEEN YEARS EXPERIENCE WITH FINGER ARTERIAL PRESSURE MONITORING: ASSESSMENT OF THE TECHNOLOGY.CARDIOVASCULAR RESEARCH. VOL. 38. ISSUE 3. P. 605 -616 | 36 | 61% | 451 |
3 | CHUNG, E , CHEN, G , ALEXANDER, B , CANNESSON, M , (2013) NON-INVASIVE CONTINUOUS BLOOD PRESSURE MONITORING: A REVIEW OF CURRENT APPLICATIONS.FRONTIERS OF MEDICINE. VOL. 7. ISSUE 1. P. 91 -101 | 34 | 52% | 20 |
4 | BARTELS, K , ESPER, SA , THIELE, RH , (2016) BLOOD PRESSURE MONITORING FOR THE ANESTHESIOLOGIST: A PRACTICAL REVIEW.ANESTHESIA AND ANALGESIA. VOL. 122. ISSUE 6. P. 1866 -1879 | 40 | 47% | 0 |
5 | FUDA, G , DENAULT, A , DESCHAMPS, A , BOUCHARD, D , FORTIER, A , LAMBERT, J , COUTURE, P , (2016) RISK FACTORS INVOLVED IN CENTRAL-TO-RADIAL ARTERIAL PRESSURE GRADIENT DURING CARDIAC SURGERY.ANESTHESIA AND ANALGESIA. VOL. 122. ISSUE 3. P. 624 -632 | 19 | 83% | 1 |
6 | SMOLLE, KH , SCHMID, M , PRETTENTHALER, H , WEGER, C , (2015) THE ACCURACY OF THE CNAP (R) DEVICE COMPARED WITH INVASIVE RADIAL ARTERY MEASUREMENTS FOR PROVIDING CONTINUOUS NONINVASIVE ARTERIAL BLOOD PRESSURE READINGS AT A MEDICAL INTENSIVE CARE UNIT: A METHOD-COMPARISON STUDY.ANESTHESIA AND ANALGESIA. VOL. 121. ISSUE 6. P. 1508 -1516 | 21 | 68% | 6 |
7 | MARTINA, JR , WESTERHOF, BE , VAN GOUDOEVER, J , DE BEAUMONT, EMFH , TRUIJEN, J , KIM, YS , IMMINK, RV , JOBSIS, DA , HOLLMANN, MW , LAHPOR, JR , ET AL (2012) NONINVASIVE CONTINUOUS ARTERIAL BLOOD PRESSURE MONITORING WITH NEXFIN (R).ANESTHESIOLOGY. VOL. 116. ISSUE 5. P. 1092-1103 | 18 | 72% | 66 |
8 | JAGOMAGI, K , TALTS, J , TAHEPOLD, P , RAAMAT, R , (2011) A COMPARISON OF DIFFERENTIAL OSCILLOMETRIC DEVICE WITH INVASIVE MEAN ARTERIAL BLOOD PRESSURE MONITORING IN INTENSIVE CARE PATIENTS.CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING. VOL. 31. ISSUE 3. P. 188 -192 | 17 | 89% | 5 |
9 | NG, KG , (2011) REVIEW OF MEASUREMENT METHODS AND CLINICAL VALIDATION STUDIES OF NONINVASIVE BLOOD PRESSURE MONITORS: ACCURACY REQUIREMENTS AND PROTOCOL CONSIDERATIONS FOR DEVICES THAT REQUIRE PATIENT-SPECIFIC CALIBRATION BY A SECONDARY METHOD OR DEVICE BEFORE USE.BLOOD PRESSURE MONITORING. VOL. 16. ISSUE 6. P. 291 -303 | 30 | 50% | 4 |
10 | WAGNER, JY , PRANTNER, JS , MEIDERT, AS , HAPFELMEIER, A , SCHMID, RM , SAUGEL, B , (2014) NONINVASIVE CONTINUOUS VERSUS INTERMITTENT ARTERIAL PRESSURE MONITORING: EVALUATION OF THE VASCULAR UNLOADING TECHNIQUE (CNAP DEVICE) IN THE EMERGENCY DEPARTMENT.SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE. VOL. 22. ISSUE . P. - | 16 | 80% | 3 |
Classes with closest relation at Level 1 |