Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
15077 | 732 | 22.5 | 46% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | LOAD FREQUENCY CONTROL | authKW | 5913845 | 24% | 79% | 179 |
2 | AUTOMATIC GENERATION CONTROL | authKW | 3527367 | 15% | 75% | 113 |
3 | LOAD FREQUENCY CONTROL LFC | authKW | 1611310 | 7% | 74% | 52 |
4 | GENERATION RATE CONSTRAINT | authKW | 1044383 | 4% | 96% | 26 |
5 | AUTOMATIC GENERATION CONTROL AGC | authKW | 928562 | 4% | 70% | 32 |
6 | GENERATION RATE CONSTRAINT GRC | authKW | 583991 | 2% | 100% | 14 |
7 | AREA CONTROL ERROR | authKW | 469271 | 2% | 75% | 15 |
8 | LFC | authKW | 463467 | 3% | 56% | 20 |
9 | MULTI AREA POWER SYSTEM | authKW | 355644 | 2% | 47% | 18 |
10 | AREA CONTROL ERROR ACE | authKW | 297949 | 1% | 71% | 10 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Engineering, Electrical & Electronic | 13088 | 77% | 0% | 560 |
2 | Energy & Fuels | 1157 | 13% | 0% | 98 |
3 | Automation & Control Systems | 783 | 7% | 0% | 52 |
4 | Computer Science, Artificial Intelligence | 405 | 7% | 0% | 49 |
5 | Thermodynamics | 366 | 6% | 0% | 46 |
6 | Instruments & Instrumentation | 213 | 6% | 0% | 45 |
7 | Physics, Nuclear | 171 | 5% | 0% | 39 |
8 | GREEN & SUSTAINABLE SCIENCE & TECHNOLOGY | 151 | 2% | 0% | 15 |
9 | Mechanics | 129 | 6% | 0% | 41 |
10 | Operations Research & Management Science | 49 | 2% | 0% | 17 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | QASSIM ENGN | 125141 | 0% | 100% | 3 |
2 | STATE SMART GRID PROTECT CONTROL | 83427 | 0% | 100% | 2 |
3 | ABIT GRP | 41714 | 0% | 100% | 1 |
4 | ADV POWER ENGN LANE | 41714 | 0% | 100% | 1 |
5 | CENT DISPATCH ADM | 41714 | 0% | 100% | 1 |
6 | CHAROTAR TECHNOL | 41714 | 0% | 100% | 1 |
7 | ELECT ENERGY RISK | 41714 | 0% | 100% | 1 |
8 | EM 2 | 41714 | 0% | 100% | 1 |
9 | ENERGY EFFICIENCY MANAGEMENT | 41714 | 0% | 100% | 1 |
10 | FUCHU COMPLEX POWER SYST PROTECT CONTROL | 41714 | 0% | 100% | 1 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS | 193486 | 19% | 3% | 142 |
2 | ELECTRIC POWER COMPONENTS AND SYSTEMS | 46649 | 6% | 3% | 44 |
3 | IEEE TRANSACTIONS ON POWER SYSTEMS | 43553 | 12% | 1% | 89 |
4 | ELECTRIC POWER SYSTEMS RESEARCH | 27295 | 7% | 1% | 54 |
5 | IET GENERATION TRANSMISSION & DISTRIBUTION | 19187 | 4% | 2% | 29 |
6 | IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS | 9910 | 3% | 1% | 24 |
7 | IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION | 8810 | 2% | 2% | 12 |
8 | ELECTRIC MACHINES AND POWER SYSTEMS | 7557 | 2% | 2% | 11 |
9 | EUROPEAN TRANSACTIONS ON ELECTRICAL POWER | 7302 | 2% | 1% | 13 |
10 | ENERGY CONVERSION AND MANAGEMENT | 6745 | 5% | 0% | 39 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | LOAD FREQUENCY CONTROL | 5913845 | 24% | 79% | 179 | Search LOAD+FREQUENCY+CONTROL | Search LOAD+FREQUENCY+CONTROL |
2 | AUTOMATIC GENERATION CONTROL | 3527367 | 15% | 75% | 113 | Search AUTOMATIC+GENERATION+CONTROL | Search AUTOMATIC+GENERATION+CONTROL |
3 | LOAD FREQUENCY CONTROL LFC | 1611310 | 7% | 74% | 52 | Search LOAD+FREQUENCY+CONTROL+LFC | Search LOAD+FREQUENCY+CONTROL+LFC |
4 | GENERATION RATE CONSTRAINT | 1044383 | 4% | 96% | 26 | Search GENERATION+RATE+CONSTRAINT | Search GENERATION+RATE+CONSTRAINT |
5 | AUTOMATIC GENERATION CONTROL AGC | 928562 | 4% | 70% | 32 | Search AUTOMATIC+GENERATION+CONTROL+AGC | Search AUTOMATIC+GENERATION+CONTROL+AGC |
6 | GENERATION RATE CONSTRAINT GRC | 583991 | 2% | 100% | 14 | Search GENERATION+RATE+CONSTRAINT+GRC | Search GENERATION+RATE+CONSTRAINT+GRC |
7 | AREA CONTROL ERROR | 469271 | 2% | 75% | 15 | Search AREA+CONTROL+ERROR | Search AREA+CONTROL+ERROR |
8 | LFC | 463467 | 3% | 56% | 20 | Search LFC | Search LFC |
9 | MULTI AREA POWER SYSTEM | 355644 | 2% | 47% | 18 | Search MULTI+AREA+POWER+SYSTEM | Search MULTI+AREA+POWER+SYSTEM |
10 | AREA CONTROL ERROR ACE | 297949 | 1% | 71% | 10 | Search AREA+CONTROL+ERROR+ACE | Search AREA+CONTROL+ERROR+ACE |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | PANDEY, SK , MOHANTY, SR , KISHOR, N , (2013) A LITERATURE SURVEY ON LOAD-FREQUENCY CONTROL FOR CONVENTIONAL AND DISTRIBUTION GENERATION POWER SYSTEMS.RENEWABLE & SUSTAINABLE ENERGY REVIEWS. VOL. 25. ISSUE . P. 318 -334 | 111 | 65% | 70 |
2 | SHAYEGHI, H , SHAYANFAR, HA , JALILI, A , (2009) LOAD FREQUENCY CONTROL STRATEGIES: A STATE-OF-THE-ART SURVEY FOR THE RESEARCHER.ENERGY CONVERSION AND MANAGEMENT. VOL. 50. ISSUE 2. P. 344 -353 | 84 | 92% | 116 |
3 | KUMAR, LP , KOTHARI, DP , (2005) RECENT PHILOSOPHIES OF AUTOMATIC GENERATION CONTROL STRATEGIES IN POWER SYSTEMS.IEEE TRANSACTIONS ON POWER SYSTEMS. VOL. 20. ISSUE 1. P. 346-357 | 86 | 87% | 53 |
4 | ARYA, Y , KUMAR, N , (2016) AGC OF A MULTI-AREA MULTI-SOURCE HYDROTHERMAL POWER SYSTEM INTERCONNECTED VIA AC/DC PARALLEL LINKS UNDER DEREGULATED ENVIRONMENT.INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS. VOL. 75. ISSUE . P. 127 -138 | 49 | 98% | 2 |
5 | SAXENA, S , HOTE, YV , (2016) DECENTRALIZED PID LOAD FREQUENCY CONTROL FOR PERTURBED MULTI-AREA POWER SYSTEMS.INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS. VOL. 81. ISSUE . P. 405 -415 | 37 | 93% | 2 |
6 | ARYA, Y , KUMAR, N , IBRAHEEM , (2016) AGC OF A TWO-AREA MULTI-SOURCE POWER SYSTEM INTERCONNECTED VIA AC/DC PARALLEL LINKS UNDER RESTRUCTURED POWER ENVIRONMENT.OPTIMAL CONTROL APPLICATIONS & METHODS. VOL. 37. ISSUE 4. P. 590 -607 | 36 | 100% | 0 |
7 | SONDHI, S , HOTE, YV , (2014) FRACTIONAL ORDER PID CONTROLLER FOR LOAD FREQUENCY CONTROL.ENERGY CONVERSION AND MANAGEMENT. VOL. 85. ISSUE . P. 343 -353 | 34 | 83% | 14 |
8 | SONDHI, S , HOTE, YV , (2016) FRACTIONAL ORDER PID CONTROLLER FOR PERTURBED LOAD FREQUENCY CONTROL USING KHARITONOV'S THEOREM.INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS. VOL. 78. ISSUE . P. 884 -896 | 37 | 73% | 1 |
9 | ARYA, Y , KUMAR, N , (2017) BFOA-SCALED FRACTIONAL ORDER FUZZY PID CONTROLLER APPLIED TO AGC OF MULTI-AREA MULTI-SOURCE ELECTRIC POWER GENERATING SYSTEMS.SWARM AND EVOLUTIONARY COMPUTATION. VOL. 32. ISSUE . P. 202 -218 | 19 | 86% | 1 |
10 | GUHA, D , ROY, PK , BANERJEE, S , (2016) LOAD FREQUENCY CONTROL OF INTERCONNECTED POWER SYSTEM USING GREY WOLF OPTIMIZATION.SWARM AND EVOLUTIONARY COMPUTATION. VOL. 27. ISSUE . P. 97 -115 | 26 | 79% | 2 |
Classes with closest relation at Level 1 |