Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
11436 | 982 | 23.1 | 55% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
8 | 4 | CARDIAC & CARDIOVASCULAR SYSTEM//PERIPHERAL VASCULAR DISEASES//CARDIOL | 1276458 |
129 | 3 | CARDIAC & CARDIOVASCULAR SYSTEM//RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING//JOURNAL OF NUCLEAR CARDIOLOGY | 67226 |
819 | 2 | DIGITAL MAMMOGRAPHY//MEDICAL PHYSICS//MAMMOGRAPHY | 11923 |
11436 | 1 | SCATTER CORRECTION//ANTISCATTER GRID//X RAY SCATTER | 982 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | SCATTER CORRECTION | authKW | 429472 | 6% | 25% | 56 |
2 | ANTISCATTER GRID | authKW | 418018 | 2% | 61% | 22 |
3 | X RAY SCATTER | authKW | 355338 | 2% | 57% | 20 |
4 | BEAM HARDENING CORRECTION | authKW | 259100 | 2% | 56% | 15 |
5 | SCATTER TO PRIMARY RATIO | authKW | 251856 | 1% | 90% | 9 |
6 | MEDICAL PHYSICS | journal | 224782 | 29% | 3% | 285 |
7 | SCATTER | authKW | 222765 | 4% | 17% | 43 |
8 | DUAL ENERGY IMAGING | authKW | 215116 | 2% | 43% | 16 |
9 | BEAM HARDENING | authKW | 204526 | 3% | 26% | 25 |
10 | PRIMARY MODULATION | authKW | 186561 | 1% | 100% | 6 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Radiology, Nuclear Medicine & Medical Imaging | 24350 | 60% | 0% | 593 |
2 | Engineering, Biomedical | 4026 | 16% | 0% | 161 |
3 | Instruments & Instrumentation | 2443 | 16% | 0% | 159 |
4 | Nuclear Science & Technology | 1489 | 12% | 0% | 118 |
5 | Materials Science, Characterization, Testing | 1480 | 5% | 0% | 49 |
6 | Imaging Science & Photographic Technology | 787 | 4% | 0% | 41 |
7 | Spectroscopy | 473 | 7% | 0% | 65 |
8 | Physics, Nuclear | 409 | 7% | 0% | 67 |
9 | Physics, Particles & Fields | 174 | 5% | 0% | 52 |
10 | Computer Science, Interdisciplinary Applications | 150 | 4% | 0% | 39 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | IMAGING DEVICES DETECTORS SENSORS | 124374 | 0% | 100% | 4 |
2 | OLSON | 65837 | 1% | 35% | 6 |
3 | CNDRI NONDESTRUCT TESTING IONIZING RADIAT | 62187 | 0% | 100% | 2 |
4 | IMAGING DEVICES SENSORS INTELLIGENCE BASED SENS | 62187 | 0% | 100% | 2 |
5 | IMAGING DEVICES SENSORS NANOENGN | 62187 | 0% | 100% | 2 |
6 | IMAGING SYST DETECTORS SENSORS | 62187 | 0% | 100% | 2 |
7 | OPT ELECT PHOTON DEVICES OPT COMMUN NETWORKS | 62187 | 0% | 100% | 2 |
8 | RSRM | 62187 | 0% | 100% | 2 |
9 | CHAIR METROL QUAL MANAGEMENT | 62183 | 0% | 50% | 4 |
10 | NONDESTRUCT TESTING USING IONIZING RADIAT | 55966 | 0% | 60% | 3 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | MEDICAL PHYSICS | 224782 | 29% | 3% | 285 |
2 | PHYSICS IN MEDICINE AND BIOLOGY | 35826 | 11% | 1% | 112 |
3 | JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY | 26029 | 2% | 4% | 21 |
4 | IEEE TRANSACTIONS ON MEDICAL IMAGING | 6383 | 3% | 1% | 28 |
5 | RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING | 4579 | 2% | 1% | 15 |
6 | TM-TECHNISCHES MESSEN | 4448 | 1% | 1% | 10 |
7 | INSIGHT | 3094 | 1% | 1% | 12 |
8 | RADIOLOGY | 2426 | 4% | 0% | 39 |
9 | CIRP ANNALS-MANUFACTURING TECHNOLOGY | 2283 | 1% | 1% | 13 |
10 | NDT & E INTERNATIONAL | 2093 | 1% | 1% | 11 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | SCATTER CORRECTION | 429472 | 6% | 25% | 56 | Search SCATTER+CORRECTION | Search SCATTER+CORRECTION |
2 | ANTISCATTER GRID | 418018 | 2% | 61% | 22 | Search ANTISCATTER+GRID | Search ANTISCATTER+GRID |
3 | X RAY SCATTER | 355338 | 2% | 57% | 20 | Search X+RAY+SCATTER | Search X+RAY+SCATTER |
4 | BEAM HARDENING CORRECTION | 259100 | 2% | 56% | 15 | Search BEAM+HARDENING+CORRECTION | Search BEAM+HARDENING+CORRECTION |
5 | SCATTER TO PRIMARY RATIO | 251856 | 1% | 90% | 9 | Search SCATTER+TO+PRIMARY+RATIO | Search SCATTER+TO+PRIMARY+RATIO |
6 | SCATTER | 222765 | 4% | 17% | 43 | Search SCATTER | Search SCATTER |
7 | DUAL ENERGY IMAGING | 215116 | 2% | 43% | 16 | Search DUAL+ENERGY+IMAGING | Search DUAL+ENERGY+IMAGING |
8 | BEAM HARDENING | 204526 | 3% | 26% | 25 | Search BEAM+HARDENING | Search BEAM+HARDENING |
9 | PRIMARY MODULATION | 186561 | 1% | 100% | 6 | Search PRIMARY+MODULATION | Search PRIMARY+MODULATION |
10 | BASIS MATERIAL DECOMPOSITION | 169284 | 1% | 78% | 7 | Search BASIS+MATERIAL+DECOMPOSITION | Search BASIS+MATERIAL+DECOMPOSITION |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | ZHAO, W , VERNEKOHL, D , ZHU, J , WANG, LY , XING, L , (2016) A MODEL-BASED SCATTER ARTIFACTS CORRECTION FOR CONE BEAM CT.MEDICAL PHYSICS. VOL. 43. ISSUE 4. P. 1736 -1753 | 49 | 83% | 1 |
2 | KLINGENBECK, K , RUHRNSCHOPF, EP , (2011) A GENERAL FRAMEWORK AND REVIEW OF SCATTER CORRECTION METHODS IN X-RAY CONE-BEAM COMPUTERIZED TOMOGRAPHY. PART 1: SCATTER COMPENSATION APPROACHES.MEDICAL PHYSICS. VOL. 38. ISSUE 7. P. 4296 -4311 | 47 | 67% | 38 |
3 | ZHAO, W , BRUNNER, S , NIU, K , SCHAFER, S , ROYALTY, K , CHEN, GH , (2015) PATIENT-SPECIFIC SCATTER CORRECTION FOR FLAT-PANEL DETECTOR-BASED CONE-BEAM CT IMAGING.PHYSICS IN MEDICINE AND BIOLOGY. VOL. 60. ISSUE 3. P. 1339 -1365 | 33 | 89% | 3 |
4 | RUHRNSCHOPF, EP , KLINGENBECK, K , (2011) A GENERAL FRAMEWORK AND REVIEW OF SCATTER CORRECTION METHODS IN CONE BEAM CT. PART 2: SCATTER ESTIMATION APPROACHES.MEDICAL PHYSICS. VOL. 38. ISSUE 9. P. 5186 -5199 | 43 | 70% | 31 |
5 | SISNIEGA, A , ZBIJEWSKI, W , XU, J , DANG, H , STAYMAN, JW , YORKSTON, J , AYGUN, N , KOLIATSOS, V , SIEWERDSEN, JH , (2015) HIGH-FIDELITY ARTIFACT CORRECTION FOR CONE-BEAM CT IMAGING OF THE BRAIN.PHYSICS IN MEDICINE AND BIOLOGY. VOL. 60. ISSUE 4. P. 1415 -1439 | 40 | 51% | 7 |
6 | CHEN, X , NISHIKAWA, RM , CHAN, ST , LAU, BA , ZHANG, L , MOU, XQ , (2013) ALGORITHMIC SCATTER CORRECTION IN DUAL-ENERGY DIGITAL MAMMOGRAPHY.MEDICAL PHYSICS. VOL. 40. ISSUE 11. P. - | 25 | 93% | 2 |
7 | MEYER, M , KALENDER, WA , KYRIAKOU, Y , (2010) A FAST AND PRAGMATIC APPROACH FOR SCATTER CORRECTION IN FLAT-DETECTOR CT USING ELLIPTIC MODELING AND ITERATIVE OPTIMIZATION.PHYSICS IN MEDICINE AND BIOLOGY. VOL. 55. ISSUE 1. P. 99 -120 | 27 | 87% | 22 |
8 | SOSSIN, A , REBUFFEL, V , TABARY, J , LETANG, JM , FREUD, N , VERGER, L , (2016) A NOVEL SCATTER SEPARATION METHOD FOR MULTI-ENERGY X-RAY IMAGING.PHYSICS IN MEDICINE AND BIOLOGY. VOL. 61. ISSUE 12. P. 4711 -4728 | 25 | 86% | 0 |
9 | LIFTON, JJ , MALCOLM, AA , MCBRIDE, JW , (2016) AN EXPERIMENTAL STUDY ON THE INFLUENCE OF SCATTER AND BEAM HARDENING IN X-RAY CT FOR DIMENSIONAL METROLOGY.MEASUREMENT SCIENCE AND TECHNOLOGY. VOL. 27. ISSUE 1. P. - | 23 | 92% | 0 |
10 | AHN, SH , CHOI, J , LEE, KC , KIM, S , LEE, R , (2014) DEVELOPMENT OF A BEAM STOP ARRAY SYSTEM WITH DUAL SCAN MODE FOR SCATTER CORRECTION OF CONE-BEAM CT.JOURNAL OF THE KOREAN PHYSICAL SOCIETY. VOL. 64. ISSUE 8. P. 1220 -1229 | 25 | 86% | 0 |
Classes with closest relation at Level 1 |