Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
11203 | 1000 | 16.1 | 53% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
2 | 4 | MATERIALS SCIENCE, MULTIDISCIPLINARY//PHYSICS, APPLIED//PHYSICS, CONDENSED MATTER | 2836879 |
703 | 3 | TACTILE SENSOR//FLUXGATE//FLUXGATE SENSOR | 6393 |
3274 | 2 | FLUXGATE//FLUXGATE SENSOR//MAGNETIC SENSORS | 1916 |
11203 | 1 | FLUXGATE//FLUXGATE SENSOR//MAGNETOMETER | 1000 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | FLUXGATE | authKW | 2257116 | 9% | 79% | 93 |
2 | FLUXGATE SENSOR | authKW | 1768609 | 7% | 79% | 73 |
3 | MAGNETOMETER | authKW | 718894 | 12% | 19% | 122 |
4 | MAGNETIC SENSORS | authKW | 584607 | 12% | 16% | 118 |
5 | ORTHOGONAL FLUXGATE | authKW | 520680 | 2% | 95% | 18 |
6 | FLUXGATE MAGNETOMETER | authKW | 458664 | 3% | 58% | 26 |
7 | MICROFLUXGATE | authKW | 335872 | 1% | 100% | 11 |
8 | THREE AXIS MAGNETOMETER | authKW | 314059 | 1% | 86% | 12 |
9 | MAGNETOMETER CALIBRATION | authKW | 284196 | 1% | 85% | 11 |
10 | MEASUREMENT | address | 237847 | 5% | 15% | 52 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Instruments & Instrumentation | 20472 | 45% | 0% | 447 |
2 | Engineering, Electrical & Electronic | 9189 | 56% | 0% | 557 |
3 | Physics, Applied | 2809 | 35% | 0% | 352 |
4 | Engineering, General | 883 | 8% | 0% | 76 |
5 | Engineering, Aerospace | 626 | 4% | 0% | 40 |
6 | Engineering, Marine | 362 | 1% | 0% | 11 |
7 | Electrochemistry | 350 | 6% | 0% | 56 |
8 | Nanoscience & Nanotechnology | 128 | 5% | 0% | 48 |
9 | Chemistry, Analytical | 95 | 6% | 0% | 57 |
10 | Materials Science, Multidisciplinary | 49 | 9% | 0% | 86 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | MEASUREMENT | 237847 | 5% | 15% | 52 |
2 | GRP CONTROL ACTITUD | 122135 | 0% | 100% | 4 |
3 | NONLINEAR DYNAM SYST GRP | 65659 | 2% | 13% | 16 |
4 | AUTOMAT PRZEMYSLOWEJ | 61068 | 0% | 100% | 2 |
5 | SENSOR SYST INTEGRAT | 61068 | 0% | 100% | 2 |
6 | SPACE PROGRAMS SPACE SCI | 61068 | 0% | 100% | 2 |
7 | O INGN MECAN | 54958 | 0% | 60% | 3 |
8 | INVEST MICRO NANOTECNOL | 52608 | 1% | 19% | 9 |
9 | INTELLIGENT SPACE SYST | 40710 | 0% | 67% | 2 |
10 | PAYLOADS RUMENTAT AREA | 40710 | 0% | 67% | 2 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | SENSORS AND ACTUATORS A-PHYSICAL | 84843 | 17% | 2% | 166 |
2 | IEEE SENSORS JOURNAL | 18775 | 6% | 1% | 60 |
3 | IEEE TRANSACTIONS ON MAGNETICS | 14352 | 13% | 0% | 126 |
4 | SENSOR LETTERS | 14344 | 3% | 2% | 30 |
5 | GEOSCIENTIFIC INSTRUMENTATION METHODS AND DATA SYSTEMS | 9702 | 1% | 5% | 7 |
6 | MEASUREMENT SCIENCE AND TECHNOLOGY | 7694 | 5% | 1% | 48 |
7 | IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT | 4167 | 4% | 0% | 35 |
8 | MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | 2611 | 2% | 1% | 17 |
9 | JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS | 2505 | 1% | 1% | 7 |
10 | SENSORS | 2057 | 3% | 0% | 26 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | FLUXGATE | 2257116 | 9% | 79% | 93 | Search FLUXGATE | Search FLUXGATE |
2 | FLUXGATE SENSOR | 1768609 | 7% | 79% | 73 | Search FLUXGATE+SENSOR | Search FLUXGATE+SENSOR |
3 | MAGNETOMETER | 718894 | 12% | 19% | 122 | Search MAGNETOMETER | Search MAGNETOMETER |
4 | MAGNETIC SENSORS | 584607 | 12% | 16% | 118 | Search MAGNETIC+SENSORS | Search MAGNETIC+SENSORS |
5 | ORTHOGONAL FLUXGATE | 520680 | 2% | 95% | 18 | Search ORTHOGONAL+FLUXGATE | Search ORTHOGONAL+FLUXGATE |
6 | FLUXGATE MAGNETOMETER | 458664 | 3% | 58% | 26 | Search FLUXGATE+MAGNETOMETER | Search FLUXGATE+MAGNETOMETER |
7 | MICROFLUXGATE | 335872 | 1% | 100% | 11 | Search MICROFLUXGATE | Search MICROFLUXGATE |
8 | THREE AXIS MAGNETOMETER | 314059 | 1% | 86% | 12 | Search THREE+AXIS+MAGNETOMETER | Search THREE+AXIS+MAGNETOMETER |
9 | MAGNETOMETER CALIBRATION | 284196 | 1% | 85% | 11 | Search MAGNETOMETER+CALIBRATION | Search MAGNETOMETER+CALIBRATION |
10 | CURRENT SENSOR | 177760 | 3% | 18% | 33 | Search CURRENT+SENSOR | Search CURRENT+SENSOR |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | RIPKA, P , (2003) ADVANCES IN FLUXGATE SENSORS.SENSORS AND ACTUATORS A-PHYSICAL. VOL. 106. ISSUE 1-3. P. 8-14 | 43 | 96% | 128 |
2 | LEI, C , LIU, Y , SUN, XC , WANG, T , YANG, Z , ZHOU, Y , (2015) IMPROVED PERFORMANCE OF INTEGRATED SOLENOID FLUXGATE SENSOR CHIP USING A BILAYER CO-BASED RIBBON CORE.IEEE SENSORS JOURNAL. VOL. 15. ISSUE 9. P. 5010 -5014 | 27 | 93% | 0 |
3 | CHOI, S , YOON, YK , KIM, SH , ALLEN, MG , (2011) NONLINEAR SENSITIVITY ENHANCEMENT OF RESONANT MICROSENSORS AND ITS APPLICATION TO LOW POWER MAGNETIC SENSING.JOURNAL OF MICROMECHANICS AND MICROENGINEERING. VOL. 21. ISSUE 4. P. - | 26 | 90% | 8 |
4 | LEI, C , SUN, XC , ZHOU, Y , (2016) REVERSE OPTIMIZATION OF AN INTEGRATED SOLENOID FLUXGATE SENSOR BASED ON CO-BASED AMORPHOUS SOFT MAGNETIC RIBBON.JOURNAL OF ELECTRONIC MATERIALS. VOL. 45. ISSUE 10. P. 5356 -5361 | 23 | 92% | 0 |
5 | TIAN, Z , REN, DH , YOU, Z , (2016) SELF-OSCILLATION-BASED FREQUENCY TRACKING FOR THE DRIVE AND DETECTION OF RESONANCE MAGNETOMETERS.SENSORS. VOL. 16. ISSUE 5. P. - | 22 | 92% | 0 |
6 | RIPKA, P , JANOSEK, M , (2010) ADVANCES IN MAGNETIC FIELD SENSORS.IEEE SENSORS JOURNAL. VOL. 10. ISSUE 6. P. 1108 -1116 | 30 | 57% | 97 |
7 | LU, CC , HUANG, J , CHIU, PK , CHIU, SL , JENG, JT , (2014) HIGH-SENSITIVITY LOW-NOISE MINIATURE FLUXGATE MAGNETOMETERS USING A FLIP CHIP CONCEPTUAL DESIGN.SENSORS. VOL. 14. ISSUE 8. P. 13815 -13829 | 20 | 91% | 5 |
8 | PANG, HF , PAN, MC , CHEN, JF , LI, J , ZHANG, Q , LUO, ST , (2016) INTEGRATED CALIBRATION AND MAGNETIC DISTURBANCE COMPENSATION OF THREE-AXIS MAGNETOMETERS.MEASUREMENT. VOL. 93. ISSUE . P. 409 -413 | 20 | 91% | 0 |
9 | HERRERA-MAY, AL , SOLER-BALCAZAR, JC , VAZQUEZ-LEAL, H , MARTINEZ-CASTILLO, J , VIGUERAS-ZUNIGA, MO , AGUILERA-CORTES, LA , (2016) RECENT ADVANCES OF MEMS RESONATORS FOR LORENTZ FORCE BASED MAGNETIC FIELD SENSORS: DESIGN, APPLICATIONS AND CHALLENGES.SENSORS. VOL. 16. ISSUE 9. P. - | 24 | 75% | 0 |
10 | DIMITROPOULOS, PD , (2005) NOISE SOURCES IN MINIATURE FLUXGATE SENSORS PART I: THEORETICAL TREATMENT.INTERNATIONAL JOURNAL OF ELECTRONICS. VOL. 92. ISSUE 9. P. 499-524 | 27 | 87% | 2 |
Classes with closest relation at Level 1 |