Class information for: |
Basic class information |
ID | Publications | Average number of references |
Avg. shr. active ref. in WoS |
---|---|---|---|
9780 | 1056 | 21.8 | 33% |
Classes in level above (level 2) |
ID, lev. above |
Publications | Label for level above |
---|---|---|
1840 | 5631 | JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH//COMPOSITE COLUMNS//ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC |
Terms with highest relevance score |
Rank | Term | Type of term | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
---|---|---|---|---|---|---|
1 | FIRE RESISTANCE | Author keyword | 68 | 28% | 20% | 206 |
2 | ARCHITECTURAL STUDIES | Address | 22 | 60% | 2% | 24 |
3 | FIRE ENGINEERING | Author keyword | 19 | 42% | 3% | 35 |
4 | THERMAL RESTRAINT | Author keyword | 18 | 89% | 1% | 8 |
5 | CATENARY ACTION | Author keyword | 15 | 38% | 3% | 31 |
6 | RESTRAINED BEAM | Author keyword | 15 | 88% | 1% | 7 |
7 | AXIAL RESTRAINT | Author keyword | 12 | 58% | 1% | 14 |
8 | TENSILE MEMBRANE ACTION | Author keyword | 11 | 57% | 1% | 13 |
9 | REVERSE CHANNEL CONNECTION | Author keyword | 11 | 100% | 1% | 6 |
10 | TRAVELLING FIRES | Author keyword | 11 | 100% | 1% | 6 |
Web of Science journal categories |
Author Key Words |
Rank | Web of Science journal category | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | FIRE RESISTANCE | 68 | 28% | 20% | 206 | Search FIRE+RESISTANCE | Search FIRE+RESISTANCE |
2 | FIRE ENGINEERING | 19 | 42% | 3% | 35 | Search FIRE+ENGINEERING | Search FIRE+ENGINEERING |
3 | THERMAL RESTRAINT | 18 | 89% | 1% | 8 | Search THERMAL+RESTRAINT | Search THERMAL+RESTRAINT |
4 | CATENARY ACTION | 15 | 38% | 3% | 31 | Search CATENARY+ACTION | Search CATENARY+ACTION |
5 | RESTRAINED BEAM | 15 | 88% | 1% | 7 | Search RESTRAINED+BEAM | Search RESTRAINED+BEAM |
6 | AXIAL RESTRAINT | 12 | 58% | 1% | 14 | Search AXIAL+RESTRAINT | Search AXIAL+RESTRAINT |
7 | TENSILE MEMBRANE ACTION | 11 | 57% | 1% | 13 | Search TENSILE+MEMBRANE+ACTION | Search TENSILE+MEMBRANE+ACTION |
8 | REVERSE CHANNEL CONNECTION | 11 | 100% | 1% | 6 | Search REVERSE+CHANNEL+CONNECTION | Search REVERSE+CHANNEL+CONNECTION |
9 | TRAVELLING FIRES | 11 | 100% | 1% | 6 | Search TRAVELLING+FIRES | Search TRAVELLING+FIRES |
10 | STEEL COLUMN | 10 | 44% | 2% | 18 | Search STEEL+COLUMN | Search STEEL+COLUMN |
Key Words Plus |
Rank | Web of Science journal category | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
---|---|---|---|---|---|
1 | THERMAL ELONGATION | 27 | 92% | 1% | 11 |
2 | HAND CALCULATION METHOD | 27 | 76% | 2% | 19 |
3 | EXPLOSION ANALYSIS | 23 | 86% | 1% | 12 |
4 | CATENARY ACTION | 23 | 70% | 2% | 19 |
5 | INTEGRATED ADAPTIVE ENVIRONMENT | 22 | 81% | 1% | 13 |
6 | MEMBRANE ACTION | 17 | 48% | 2% | 26 |
7 | RANKINE APPROACH | 17 | 100% | 1% | 8 |
8 | MODELING MEMBRANE ACTION | 15 | 71% | 1% | 12 |
9 | FRAMED BUILDINGS | 15 | 88% | 1% | 7 |
10 | STEEL COLUMNS | 14 | 41% | 2% | 26 |
Journals |
Rank | Web of Science journal category | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
---|---|---|---|---|---|
1 | JOURNAL OF FIRE PROTECTION ENGINEERING | 2 | 14% | 1% | 14 |
Reviews |
Title | Publ. year | Cit. | Active references |
% act. ref. to same field |
---|---|---|---|---|
Travelling fires for structural design-Part I: Literature review | 2012 | 8 | 9 | 89% |
Fire hazard in bridges: Review, assessment and repair strategies | 2012 | 17 | 21 | 48% |
Performance of beam-to-column joints in fire - A review | 2008 | 17 | 23 | 87% |
Performance Based Fire Engineering Research of Steel and Composite Structures: a Review of Joint Behaviour | 2011 | 5 | 29 | 86% |
Unbonded post tensioned concrete in fire: A review of data from furnace tests and real fires | 2011 | 9 | 10 | 60% |
Review of post-earthquake fire hazard to building structures | 2008 | 14 | 3 | 67% |
Performance of steel-concrete composite structures in fire | 2005 | 17 | 46 | 96% |
Experimental review of the homogeneous temperature assumption in post-flashover compartment fires | 2010 | 11 | 5 | 40% |
Fire induced progressive collapse of steel building structures: A review of the mechanisms | 2015 | 0 | 23 | 61% |
Address terms |
Rank | Address term | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
---|---|---|---|---|---|
1 | ARCHITECTURAL STUDIES | 22 | 60% | 2.3% | 24 |
2 | ARUP FIRE | 6 | 80% | 0.4% | 4 |
3 | ASSET MANAGEMENT SCI | 4 | 67% | 0.4% | 4 |
4 | MANCHESTER CIVIL CONSTRUCT ENGN | 4 | 27% | 1.1% | 12 |
5 | FIRE ENGN SECT | 3 | 100% | 0.3% | 3 |
6 | CIENCIA TECNOL HORMIGON ICITECH | 3 | 21% | 1.0% | 11 |
7 | BRE FIRE SAFETY ENGN | 1 | 15% | 0.9% | 9 |
8 | LEHRSTUHL METALLBAU | 1 | 38% | 0.3% | 3 |
9 | FIRE ISTANCE TEAM | 1 | 100% | 0.2% | 2 |
10 | DISASTER PREVENT SCI SAFETY TECHNOL | 1 | 20% | 0.4% | 4 |
Related classes at same level (level 1) |
Rank | Relatedness score | Related classes |
---|---|---|
1 | 0.0000269013 | SPALLING//EXPLOSIVE SPALLING//TRANSIENT STRAIN |
2 | 0.0000181271 | CHARRING RATE//ISO FIRE EXPOSURE//GYPSUM PLASTERBOARD |
3 | 0.0000180388 | PROGRESSIVE COLLAPSE//DISPROPORTIONATE COLLAPSE//COLUMN LOSS |
4 | 0.0000146242 | COMPOSITE COLUMNS//ELLIPTICAL HOLLOW SECTIONS//CONCRETE FILLED STEEL TUBES |
5 | 0.0000143767 | FRACTURE TOUGHNESS ASSESSMENT//SHORT TIME CREEP//FRACTURE TOUGHNESS CALCULATION |
6 | 0.0000120420 | JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH//ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC//COMPONENT METHOD |
7 | 0.0000081381 | COLD FORMED STEEL//DIRECT STRENGTH METHOD//THIN-WALLED STRUCTURES |
8 | 0.0000063566 | FIRE SAFETY JOURNAL//TUNNEL FIRE//COMPARTMENT FIRE |
9 | 0.0000060387 | PATCH LOADING//CORRUGATED WEB//LONGITUDINAL STIFFENERS |
10 | 0.0000050528 | TUBULAR JOINT//CIRCULAR HOLLOW SECTION CHS//HOT SPOT STRESS |