Class information for: |
Basic class information |
ID | Publications | Average number of references |
Avg. shr. active ref. in WoS |
---|---|---|---|
24027 | 273 | 20.7 | 37% |
Classes in level above (level 2) |
ID, lev. above |
Publications | Label for level above |
---|---|---|
307 | 17784 | IEEE TRANSACTIONS ON POWER SYSTEMS//IEEE TRANSACTIONS ON POWER DELIVERY//INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS |
Terms with highest relevance score |
Rank | Term | Type of term | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
---|---|---|---|---|---|---|
1 | PRONY ANALYSIS | Author keyword | 6 | 27% | 7% | 18 |
2 | ELECTROMECHANICAL MODE IDENTIFICATION | Author keyword | 4 | 75% | 1% | 3 |
3 | NORDIC 32 BUS SYSTEM | Author keyword | 3 | 100% | 1% | 3 |
4 | GENERALIZED SPECTRAL ANALYSIS | Author keyword | 2 | 67% | 1% | 2 |
5 | IBRAHIM TIME DOMAIN ITD METHOD | Author keyword | 2 | 67% | 1% | 2 |
6 | RINGDOWN DETECTION | Author keyword | 2 | 67% | 1% | 2 |
7 | STUDIES PROGRAM ELECT ENGN | Address | 2 | 67% | 1% | 2 |
8 | N4SID | Author keyword | 2 | 33% | 1% | 4 |
9 | ELECTROMECHANICAL MODES | Author keyword | 1 | 25% | 2% | 5 |
10 | MODE METER | Author keyword | 1 | 100% | 1% | 2 |
Web of Science journal categories |
Author Key Words |
Rank | Web of Science journal category | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | PRONY ANALYSIS | 6 | 27% | 7% | 18 | Search PRONY+ANALYSIS | Search PRONY+ANALYSIS |
2 | ELECTROMECHANICAL MODE IDENTIFICATION | 4 | 75% | 1% | 3 | Search ELECTROMECHANICAL+MODE+IDENTIFICATION | Search ELECTROMECHANICAL+MODE+IDENTIFICATION |
3 | NORDIC 32 BUS SYSTEM | 3 | 100% | 1% | 3 | Search NORDIC+32+BUS+SYSTEM | Search NORDIC+32+BUS+SYSTEM |
4 | GENERALIZED SPECTRAL ANALYSIS | 2 | 67% | 1% | 2 | Search GENERALIZED+SPECTRAL+ANALYSIS | Search GENERALIZED+SPECTRAL+ANALYSIS |
5 | IBRAHIM TIME DOMAIN ITD METHOD | 2 | 67% | 1% | 2 | Search IBRAHIM+TIME+DOMAIN+ITD+METHOD | Search IBRAHIM+TIME+DOMAIN+ITD+METHOD |
6 | RINGDOWN DETECTION | 2 | 67% | 1% | 2 | Search RINGDOWN+DETECTION | Search RINGDOWN+DETECTION |
7 | N4SID | 2 | 33% | 1% | 4 | Search N4SID | Search N4SID |
8 | ELECTROMECHANICAL MODES | 1 | 25% | 2% | 5 | Search ELECTROMECHANICAL+MODES | Search ELECTROMECHANICAL+MODES |
9 | MODE METER | 1 | 100% | 1% | 2 | Search MODE+METER | Search MODE+METER |
10 | INTERAREA OSCILLATIONS | 1 | 15% | 3% | 8 | Search INTERAREA+OSCILLATIONS | Search INTERAREA+OSCILLATIONS |
Key Words Plus |
Rank | Web of Science journal category | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
---|---|---|---|---|---|
1 | ELECTROMECHANICAL MODES | 13 | 58% | 5% | 15 |
2 | PRONY ANALYSIS | 10 | 32% | 9% | 25 |
3 | ROBUST RLS METHODS | 8 | 52% | 4% | 11 |
4 | RESPONSE SIGNALS | 6 | 80% | 1% | 4 |
5 | SYSTEM RESPONSE SIGNALS | 4 | 67% | 1% | 4 |
6 | AMBIENT DATA | 3 | 27% | 3% | 9 |
7 | POWER SYSTEM RESPONSE | 3 | 33% | 3% | 7 |
8 | PRONY | 2 | 36% | 2% | 5 |
9 | SYNCHROPHASOR MEASUREMENTS | 1 | 50% | 1% | 2 |
10 | ELECTROMECHANICAL OSCILLATIONS | 1 | 18% | 1% | 4 |
Journals |
Reviews |
Title | Publ. year | Cit. | Active references |
% act. ref. to same field |
---|---|---|---|---|
Mode Shape Estimation Algorithms Under Ambient Conditions: A Comparative Review | 2013 | 5 | 11 | 91% |
Research focuses and advance technologies of smart grid in recent years | 2012 | 1 | 59 | 14% |
How much is energy research & development worth as insurance? | 1999 | 9 | 8 | 13% |
Address terms |
Rank | Address term | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
---|---|---|---|---|---|
1 | STUDIES PROGRAM ELECT ENGN | 2 | 67% | 0.7% | 2 |
2 | POWER SYST ANAL | 1 | 30% | 1.1% | 3 |
3 | DISPATCH COMMUN | 1 | 50% | 0.4% | 1 |
4 | ENERGY SYST INNOVAT ESI | 1 | 50% | 0.4% | 1 |
5 | ENVIRONM METAB ANAL TEAM | 1 | 50% | 0.4% | 1 |
6 | FLIGHT PROJECTS DIRECTORATE | 1 | 50% | 0.4% | 1 |
7 | MENT ELECT ENGN | 1 | 50% | 0.4% | 1 |
8 | SICHUAN ELECT POWER | 1 | 50% | 0.4% | 1 |
9 | TRANSMISS OPERAT PLANNING | 0 | 33% | 0.4% | 1 |
10 | UNIDAD INGN ESPECIALIZADA | 0 | 33% | 0.4% | 1 |
Related classes at same level (level 1) |
Rank | Relatedness score | Related classes |
---|---|---|
1 | 0.0000249947 | TRANSIENT STABILITY//DYNAMIC SECURITY//TRANSIENT ENERGY MARGIN |
2 | 0.0000238455 | POWER SYSTEM STABILIZER//POWER SYSTEM STABILIZERS//FACTS |
3 | 0.0000216278 | LOAD MODELING//POWER SYSTEM LOAD MODELING//CONSERVATION VOLTAGE REDUCTION CVR |
4 | 0.0000156630 | POWER QUALITY PQ//POWER QUALITY EVENTS//ELECT AREA |
5 | 0.0000121464 | POWER SYSTEM STATE ESTIMATION//STATE ESTIMATION//POWER DOMINATION |
6 | 0.0000118151 | EMPIRICAL MODE DECOMPOSITION//EMPIRICAL MODE DECOMPOSITION EMD//BEDROSIAN IDENTITY |
7 | 0.0000088206 | STANDSTILL TESTS//SYNCHRONOUS MACHINES//SYNCHRONOUS MACHINE |
8 | 0.0000079035 | VOLTAGE STABILITY//VOLTAGE COLLAPSE//AVAILABLE TRANSFER CAPABILITY |
9 | 0.0000077936 | OPERATIONAL MODAL ANALYSIS//SUBSPACE IDENTIFICATION//STOCHASTIC SUBSPACE IDENTIFICATION |
10 | 0.0000076820 | EIGEN COORDINATES METHOD//PSEUDO PHASE PLANE//N FOLD CONVOLUTION |